Multiple breath washout (MBW) of inert gas for assessment of airway disease in children is an emerging technique. In many studies Lung Clearance Index (LCI), derived from multiple breath washout of SF6, is more able to detect early or mild lung disease than standard lung function measurements. It is also able to detect very early lung disease in progressive conditions such as Cystic Fibrosis (CF). Where infants born with this condition were thought to have minimal lung disease activity, LCI is higher in these children than healthy controls. Lack of available commercial devices has hampered expansion of this technique to centres other than specialist research teams. Innocor (Innovision, Dk), a photoacoustic mass spectrometer capable of performing multiple breath washout, was adapted within this research group for use in adults. This thesis describes the setup, adaptation and validation of Innocor for use in children. In 4 studies, healthy controls, children with asthma and children with CF were recruited to perform MBW. In one study, 29 healthy controls and 31 children with asthma were recruited. Healthy controls performed 1 set of washouts, establishing a normative range. Children with asthma performed measurements before and after bronchodilator. Results showed increased LCI in children with asthma even though they were clinically stable as defined by symptoms. LCI stayed high even following bronchodilator suggesting evidence of residual airway disease in well controlled asthmatics despite adequate symptom control. To investigate short term variability of MBW measurements, two other studies recruited 18 children with CF in each. They performed measurements before and after standard physiotherapy manoeuvres and during sitting and lying posture. LCI did not change significantly after airway clearance physiotherapy, compared with children who did no intervention. Variability was high in both groups however suggesting CF lung disease is a complex interaction of changing ventilation in adjacent lung units. Lying posture induced greater changes in lung function in children with CF than controls. LCI appears to be more sensitive to this change than standard lung function measurements (spirometry). In another study 32 children with CF were recruited to perform serial lung function measurements over 18 months. These were data collected as part of the UK Cystic Fibrosis Gene Therapy Consortium (CFGTC) clinical studies in preparation for planned gene therapy trials. LCI appears comparable to FEV1 and may be able to detect another aspect of airway disease. All initial studies were performed in older children (>5yrs). The basic Innocor device is unsuitable for testing of younger patients with low breath volume and high respiratory rate. In-house adaptations following detailed lung model experimentation led to a faster analyser response, potentially capable of MBW in younger children. The second part of this thesis concerns lab experiments and an in-vivo comparison with the current gold-standard MBW device, a respiratory mass spectrometer. 16 healthy volunteers and 9 children with CF were recruited. Ages ranged from 0.4 yrs to 49 yrs. Innocor values for lung volume estimation compared favourably with the mass spectrometer. No evidence of bias caused by Innocor error was seen, however intra-test variability was rather high, reducing the precision of the results. These studies indicate Innocor is a robust, simple to use device with potential as a commercial lung function system. Modifications were made to make it suitable for use in all ages. Further development will need to focus on the patient interface and software, which is the domain of the manufacturers. The experiments contained in this thesis are therefore of interest to the wider respiratory research community as well as manufacturers of MBW devices.
Identifer | oai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:764153 |
Date | January 2014 |
Creators | Macleod, Kenneth Alexander |
Contributors | Porteous, David ; Cunningham, Steve ; Innes, James |
Publisher | University of Edinburgh |
Source Sets | Ethos UK |
Detected Language | English |
Type | Electronic Thesis or Dissertation |
Source | http://hdl.handle.net/1842/33295 |
Page generated in 0.0022 seconds