Return to search

Determinação de salinidade em meio aquoso empregando radiação gama para predição de frações de volume

Submitted by Almir Azevedo (barbio1313@gmail.com) on 2017-04-26T11:35:46Z
No. of bitstreams: 1
dissertação mestrado ien 2016 Caroline M Barbosa.pdf: 2146360 bytes, checksum: bb7e3963b9807e214b615443710004e5 (MD5) / Made available in DSpace on 2017-04-26T11:35:46Z (GMT). No. of bitstreams: 1
dissertação mestrado ien 2016 Caroline M Barbosa.pdf: 2146360 bytes, checksum: bb7e3963b9807e214b615443710004e5 (MD5)
Previous issue date: 2016-02 / Na extração offshore, a água produzida pode apresentar características geoquímicas que correspondem à mistura de água de formação (água conata) e da água do mar (água de injeção) e o comportamento físico-químico da água injetada permite variação considerável no índice de salinidade alterando a relação água/óleo e tornando-se difícil prever por cálculos do balanço de massa devido à grande anisotropia dos reservatórios. Um dos métodos para se avaliar o comportamento da água de injeção é determinar o índice de salinidade (cloretos) da água produzida em cada poço. Os fluidos oriundos desta extração são separados nas suas diferentes frações: líquida (hidrocarbonetos e compostos orgânicos e água) e gasosa (gás natural). Para a predição das frações de volume em regimes multifásicos torna-se necessário um monitoramento em tempo real da qualidade da água (índice de salinidade). A densitometria gama é uma técnica não invasiva indicada para medir o índice de salinidade da água e determinar sua interferência no sinal registrado por um detector cintilador. No entanto, essa técnica mostra alta dependência na composição química da fase aquosa, o que afeta consideravelmente a interação da radiação gama de baixa energia com a água salinizada. Este trabalho apresenta uma metodologia baseada nos princípios de atenuação de raios gama, por meio de simulações de Monte Carlo para calcular a influência da salinidade em medidas utilizando meios aquosos. O sistema de detecção utiliza um detector NaI(Tl) e duas fontes de radiação gama (137Cs e 241Am) para calcular o feixe transmitido visando obter os coeficientes de atenuação mássico em amostras salinas. Os sais NaCl, KCl e MgCl2 foram investigados variando o percentual de concentração em 2%, 6%, 10% e 14%, na faixa de energia de 20 a 800 keV. A validação experimental utilizou a amostra de cloreto de sódio (concentrações de 2,5; 2,0; 1,5 e 1,0 Molar) utilizando os valores de radioisótopos conhecidos, com 59,54 keV (241Am); 356,02 keV (133Ba); 662 keV (137Cs); 1,27 MeV (22Na) e 1,33 MeV (60Co). O código computacional MCNP-X foi utilizado para desenvolver a geometria apropriada a ser implementada experimentalmente. Os resultados obtidos na simulação foram validados experimentalmente e comparados valores teóricos do NIST e XCOM apontando boa concordância. Os resultados indicam que é possível utilizar esta metodologia para correção do índice de salinidade em cálculos de frações de volume ou ainda para diferenciar a água de produção da água de injeção utilizando fontes de baixa energia. / In the offshore extraction, the produced water can present geometric characteristics that correspond to the mixture of forming water and the sea water (injection water) and the physical-chemical behavior of the injected water to allow the considerable variation of the salinity index Altering the water / oil ratio and making it difficult to predict mass balance calculations due to the large anisotropy of the reservoirs. One of the methods to evaluate the behavior of the injection water is to determine the salinity index (chlorides) of the water produced in each well. The fluids derived from this extraction are separated into their different fractions: liquid (hydrocarbons and organic compounds and water) and gas (natural gas). A real-time monitoring of water quality (salinity index) is required for pre-editing volume fractions in multiphase regimes. Densitometry is a noninvasive technique indicated to measure the water salinity index and determine its unsigned interference recorded by a scintillator. However, this technique shows high dependence on the chemical composition of the aqueous phase, which considerably affect the interaction of low energy gamma radiation with saline water. This work presents a methodology with our principles of gamma ray attenuation, using Monte Carlo simulations to calculate an influence of salinity on measurements using aqueous medium. The detection system uses a NaI(Tl) detector and two gamma radiation sources (137Cs and 241Am) to calculate the transmitted beam to obtain the maxima attenuation coefficients in salt samples. The NaCl, KCl and MgCl2 salts were investigated by varying the concentration percentage by 2%, 6%, 10% and 14%, in the energy range of 20 to 800 keV. Experimental validation uses a sample of sodium chloride (concentrations of 2.5, 2.0, 1.5 and 1.0 molar) using the known radioisotope values with 59.54 keV (241Am); 356.02 keV (133Ba); 662 keV (137Cs); 1.27 MeV (22Na) and 1.33 MeV (60Co). The MCNP-X computational code was used to develop an appropriate geometry to be implemented experimentally. The results obtained in the simulation were experimentally validated and the theoretical values of NIST and XCOM were compared with good agreement. The results indicate that the methodology for the correction of salinity index in calculations of volume fractions or to differentiate one from the production of injection water in low energy sources.

Identiferoai:union.ndltd.org:IBICT/oai:carpedien.ien.gov.br:ien/1829
Date02 1900
CreatorsBarbosa, Caroline Mattos Barbosa, Instituto de Engenharia Nuclear
ContributorsSalgado, César Marques, Brandão, Luís Eduardo Barreira, Santos, Rubens Souza dos, Silva, Ademir Xavier da, Brandão, Luis Eduardo Barreira, Salgado, César Marques
PublisherInstituto de Engenharia Nuclear, Programa de pós-graduação em Ciência e Tecnologia Nucleares, IEN, Brasil, Instituto de Engenharia Nuclear
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional do IEN, instname:Instituto de Engenharia Nuclear, instacron:IEN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds