My master’s thesis deals with the problems of NOx abatement that are included in flue gases. The accent is put on combined flue gases treatment throug ceramic candles, where the deposited catalyst enables NOx reduction throug the method of selective catalytic reduction. The main aim of my master’s thesis has been the design of experimental equipment for current removal of gas pollutants (dioxins, VOC and NOx) and fly-ash on catalitic ceramic candle. Design of experimental equipment consisted in the calculation of basic characteristics like pipe diameter, filtration chamber diameter, heater performance etc. During the design it was necessary to build pressure drop model that was split into head loss of ceramic candle and piping system. For the evaluation of experimentally measured data and for description of ongoing catalytic reaction in various operating conditions was made prediction model of catalytical filter. The last chapter deals with planned experimental testings.