Return to search

O papel do diâmetro e da velocidade de fluxo carotídeos na predição de risco cardiovascular em hipertensos = The role of carotid diameter and flow velocity in the prediction of cardiovascular risk in hypertensive subjects / The role of carotid diameter and flow velocity in the prediction of cardiovascular risk in hypertensive subjects

Orientador: Andrei Carvalho Sposito / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T12:32:38Z (GMT). No. of bitstreams: 1
Bellinazzi_VeraRegina_D.pdf: 1427871 bytes, checksum: 13c49eabda6b5a189f64c4a1db75108b (MD5)
Previous issue date: 2014 / Resumo: O ultrassom da artéria carótida tem sido proposto como uma maneira de melhorar a predição de eventos cardiovasculares (CV). Apesar da espessura íntima-média (EIM) carotídea ter sido extensivamente associada a eventos CV, o acréscimo desta medida a algoritmos de predição de risco resultou em pouco ou nenhum ganho adicional à predição de risco. A proposta deste estudo foi comparar a performance da EIM, diâmetro sistólico (DS), velocidade de fluxo sistólico (VFS) e a razão VFS/DS carotídeos como preditores de eventos CV maiores em uma amostra de indivíduos hipertensos. Uma coorte de 403 pacientes hipertensos (idade media 59.2?12.4 anos; 42% homens) foi acompanhada por uma mediana de 1260 (714) dias, e 27 indivíduos sofreram eventos CV maiores. No início do seguimento, os participantes realizaram avaliação clínica, laboratorial, ecocardiográfica e ultrassonográfica de carótida. Os indivíduos com baixa (mediana) DS apresentaram um pior desfecho clinico quando comparados com aqueles com baixa VFS ou alto DS isoladamente, o que sugere um efeito aditivo destas duas variáveis. A curva atuarial do tempo para o evento CV maior demonstrou pior desfecho para indivíduos com baixo índice VFS/DS comparado com aqueles com alto VFS/DS (p<0.001). Na análise de regressão de Cox ajustada para EIM carotídea e alto-risco CV definido clinicamente, baixo índice VFS/DS manteve-se significativamente associado a eventos CV maiores (Exp(B)[95%CI]=3.69[1.37-9.96]; p=0.01). Além disso, as áreas sobre a curva ROC foram para alto risco CV (0.612; p=0.051), alta EIM (0.601; p=0.009) e baixo índice VFS/DS (0.669; p=0.003) usando eventos CV maiores como desfecho binário. Enfim, concluímos que baixo índice VFS/DS está associado a pior desfecho CV em pacientes hipertensos independente de modelos de predição de risco CV e da EIM carotídea / Abstract: Carotid artery ultrasound examination has been proposed as a way to improve cardiovascular (CV) events prediction. Although carotid intima-media thickness (IMT) has been extensively associated with CV events, modest or even no improvements in prediction were gained by adding this parameter to prediction models. The aim of this study was to compare the performance of common carotid IMT, diameter (AD), flow velocity (FV) and FV/AD ratio as predictors of major CV events (MACE) in a sample of hypertensive subjects. A cohort of 403 hypertensive patients (mean age, 59.2?12.4 years; 42% men) was followed-up for a median of 1260(714) days, and 27 subjects suffered MACE. At baseline, participants were evaluated by clinical, laboratory, echocardiographic and carotid ultrasound analysis. Patients with low (median) AD presented the worse clinical outcome as compared with those with isolated low FV or high AD suggesting an additive effect of these two variables. Actuarial analysis of time to MACE demonstrated worse outcome for individuals with low FV/AD ratio compared to those with high FV/AD ratio (p<0.001). In Cox-regression analyses adjusted for carotid IMT and clinically-defined high CV risk, low FV/AD ratio remained significantly associated with MACE (Exp(B)[95%CI]=3.69[1.37-9.96]; p=0.01). Furthermore, the areas under the receiver-operating curves (C-statistics) were for clinically defined high-risk (0.612; p=0.051), high IMT (0.601; p=0.009) and low FV/AD ratio (0.669; p=0.003) using MACE as a binary outcome. In conclusion, low FV/AD ratio is associated with a poor outcome in hypertensive patients independent of CV prediction models and carotid IMT / Doutorado / Clinica Medica / Doutora em Clínica Médica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/308158
Date24 August 2018
CreatorsBellinazzi, Vera Regina, 1972-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Sposito, Andrei Carvalho, 1967-, Zornoff, Leonardo Antonio Mamede, Pereira, Alexandre Da Costa, Alegre, Sarah Monte, Tsukumo, Daniela Miti Lemos
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Clínica Médica
Source SetsIBICT Brazilian ETDs
LanguageMultilíngua
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format83 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds