Orientador: Isabel Cristina Sales Fontes Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-24T08:24:02Z (GMT). No. of bitstreams: 1
Oshita_Daniele_D.pdf: 4645263 bytes, checksum: 6628dba7b8449d1cf1f86afa3dcae9e2 (MD5)
Previous issue date: 2013 / Resumo: Este trabalho envolve o desenvolvimento, a otimização e a validação de um método analítico para determinação de multirresíduos de agrotóxicos em amostras de morango, por cromatografia líquida acoplada à espectrometria de massas sequencial (LC-MS/MS). No preparo de amostra utilizou o método QuEChERS (quick, easy, cheap, effective, rugged and safe), que foi testado nas três versões, Original, AOAC Official Method e European Committee for Standardization (CEN) Standard Method EN 15662, além da versão CEN 15662 modificada. Também foram otimizados os solventes de extração, massas do agente secante e, na etapa de clean-up por extração em fase sólida dispersiva (d-SPE), o sorvente comercial PSA (primary secondary amine), alguns preparados no laboratório à base de polímeros de siloxano, como octadecil, octil, amino, fenil, e a mistura PSA e octadecil. As avaliações dos métodos foram baseadas, principalmente, nos valores de recuperação e nos estudos sobre o uso de diferentes sorventes, outros parâmetros que estimam a eficiência do clean-up também foram utilizados, como aspecto físico do extrato final, quantidade de coextratos da matriz, obtida por medidas gravimétricas, e efeito matriz. O método desenvolvido foi validado por meio dos parâmetros analíticos de seletividade, limite de detecção (LOD), limite de quantificação (LOQ), linearidade, exatidão e precisão, conforme o guia Sanco para análises de resíduos de agrotóxicos em alimentos e, posteriormente, amostras comerciais de morango da região de Campinas foram analisadas. O método validado por LC-MS/MS apresentou-se seletivo, preciso, exato e atingiu concentrações abaixo dos respectivos limites máximos de resíduos (LMR) para determinação de agrotóxicos em morango. Este método foi transferido para cromatografia líquida de ultra eficiência (UHPLC), que mostrou redução no tempo de análise, na vazão da fase móvel (FM) e no volume de injeção de amostra e da FM, e similaridade na detectabilidade dos analitos / Abstract: This work involves the development, optimization and validation of an analytical method for multiresidue determination of pesticides in strawberry samples by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Sample preparation used the QuEChERS (quick, easy, cheap, effective, rugged and safe) method, which was tested in three versions, Original, AOAC Official Method and European Committee for Standardization (CEN) Standard Method EN 15662, and also CEN 15662 modified version. The factores optimized were extraction solvents, amount of drying agent and in the clean-up step by dispersive solid phase extraction (d-SPE), the commercial sorbent PSA (primary secondary amine), several prepared in the laboratory based on siloxane polymers, such as octadecyl, octyl, amine, phenyl, and the mixture PSA and octadecyl. The evaluation of the methods was based mainly on the recovery values and for the study of different sorbents, other parameters that estimate the efficiency of the clean-up were also used such as the physical aspect of the final extract, the amount of interference matrix obtained using gravimetric measurements, and the matrix effect. The developed method was validated by the analytical parameters of selectivity, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy and precision, as described in the Sanco guide for analysis of pesticide residues in foods. After, commercial strawberry samples from the Campinas region were analyzed. The validated method by LC-MS/MS was selective, precise, accurate and reached levels below the respective maximum residue limits (MRLs) for the determination of pesticides in strawberries. This method was transferred to ultra high performance liquid chromatography (UHPLC), which showed a reduction in analysis time, the mobile phase (MP) flow rate and the injection volume of the sample and MP, and similarity in the detectability of the analytes / Doutorado / Quimica Analitica / Doutora em Ciências
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/250530 |
Date | 12 December 2013 |
Creators | Oshita, Daniele, 1981 |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Jardim, Isabel Cristina Sales Fontes, 1953-, Adaime, Martha Bohrer, Faria, Anizio Marcio de, Junior, Ivo Milton Raimundo, Collins, Carol Hollingworth |
Publisher | [s.n.], Universidade Estadual de Campinas. Instituto de Química, Programa de Pós-Graduação em Química |
Source Sets | IBICT Brazilian ETDs |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 143 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0018 seconds