Horský hotel ve Velkých Losinách / Mountain hotel in Velké Losiny

The work deals with the design of a load-bearing wooden structure of a mountain hotel in the foothills of the Jeseníky Mountains. It is a building without cellar, two floors and a attic room. The floor plan of the building is 17 x 30 m with a porch of 3 x 10 m. Height of the building up to the ridge is 13.2 m. The design of the roof structure has been chosen from 2 different variants. Material usage consist of grown wood of class C24, glued laminated wood of class GL32h and steel S355. Static analysis was calculated by Dlubal RFEM software.