The thesis consists of two basic parts. The first research part creates an introduction to the root zone wastewater treatment plants. It contains mainly causes of filter environment colmation and its theoretical solution methods, which are further solved in the laboratory. The master’s thesis attempts to find a simple way, which would in future be possible to evaluate the rate of sedimentation of the sludge material, which causes filtration environment colmation. Results of developed methodology will be used in practice by washing colmated filtration material, respectively colmatant separation in sedimentation tank. The thesis focuses to verify the possibility flocculation and mineralization of sludge, which adheres to the surface of the filtration material. The solution lies in the observation of sedimentation rate (after previous dilution) using by the turbidimetric method, based on the beam-column passage through muddy water. The results show that it is not critical ambient temperature, but the time effect of natural mineralization in combination with moisture (dry matter concentration, the amount of water). The present thesis evaluates the possibilities and application method, leading to the natural regeneration of the filtration material exposed to natural climatic conditions.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:225490 |
Date | January 2012 |
Creators | Burešová, Hana |
Contributors | Rozkošný,, Miloš, Kriška-Dunajský, Michal |
Publisher | Vysoké učení technické v Brně. Fakulta stavební |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |