Uma proposta para detecção e compensação dos efeitos causados pela saturação dos núcleos dos transformadores de corrente utilizados em circuitos de proteção

Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-09T12:23:12Z
No. of bitstreams: 1
brunomontesanoschettino.pdf: 5340904 bytes, checksum: 74fca2465789ca0f91c3c975abb30248 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T13:31:38Z (GMT) No. of bitstreams: 1
brunomontesanoschettino.pdf: 5340904 bytes, checksum: 74fca2465789ca0f91c3c975abb30248 (MD5) / Made available in DSpace on 2016-07-13T13:31:38Z (GMT). No. of bitstreams: 1
brunomontesanoschettino.pdf: 5340904 bytes, checksum: 74fca2465789ca0f91c3c975abb30248 (MD5)
Previous issue date: 2012-12-03 / Este trabalho apresenta uma proposta para efetuar a compensação dos efeitos causados pela saturação dos núcleos dos Transformadores de Corrente (TC) utilizados em circuitos de proteção, através da correção do valor eficaz da componente alternada da corrente distorcida do secundário. O problema foi dividido em duas etapas: a detecção e a compensação da saturação. Para a etapa de detecção foi desenvolvido um método novo, denominado método da função primeira diferença do filtro de Lanczos, que mostrou-se mais imune a ruídos que os métodos tradicionais existentes na literatura. Na etapa de compensação da saturação, foi utilizado o método de estimação para modelos lineares. Os métodos foram implementados em MATLAB e testados em correntes distorcidas geradas de duas formas distintas: através de um simulador de TC operando na região de saturação desenvolvido em MATLAB e através de simulações realizadas em um simulador digital em tempo real (RTDS). Os resultados preliminares apontam para um algoritmo robusto, independente das características dinâmicas do TC, da corrente de falta e de outros fatores externos. Além disso, o tempo de resposta mostrou-se compatível com a possibilidade de implementação em tempo real, atendendo às necessidades da área de proteção dos Sistemas Elétricos de Potência. / This work presents a proposal to perform a compensation of the effects due to saturation of Current Transformers (CT) cores used in circuit protection, by correcting the root mean square (RMS) value of the alternate component (AC) of the secondary distorted current. The problem was divided into two phases: detection and compensation of saturation. For the step of detection, a new method was developed, called first difference function of Lanczos filter method, which has proved more immune to noise than traditional methods in the literature. In the step of compensation of saturation, was used a estimation method for linear models. The methods were implemented in MATLAB and tested on distorted currents generated in two ways: through a CT simulator operating in the saturation region developed in MATLAB and through simulations in a real time digital simulator (RTDS). Preliminary results indicate a robust algorithm, independent of the dynamic characteristics of TC, fault current and other external factors. Furthermore, the response time was showed compatible with the possibility of real time implementation, attending to the needs of the protection area of Electric Power Systems.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/1786
Date03 December 2012
CreatorsSchettino, Bruno Montesano
ContributorsDuque, Carlos Augusto, Silveira, Paulo Márcio da, Barbosa, Pedro Gomes, Bretas, Arturo Suman
PublisherUniversidade Federal de Juiz de Fora, Programa de Pós-graduação em Engenharia Elétrica, UFJF, Brasil, Faculdade de Engenharia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0056 seconds