Return to search

Influência da adição de reforço e ciclagem mecânica na resistência ao impacto de resinas para base e para reembasamento imediato

Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-07-20Bitstream added on 2014-06-13T20:25:46Z : No. of bitstreams: 1
perez_lec_dr_arafo.pdf: 945544 bytes, checksum: 1953b0c131a1dd92caf810e902b96fd9 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da adição de reforço e ciclagem mecânica sobre a resistência ao impacto, por meio dos testes Charpy (C) e queda livre de dardo (QL), para resinas de base e para reembasamento imediato. Para o teste C, corpos-de-prova (60x6x2 mm) foram confeccionados com as resinas Lucitone 550 (L) e Vipi Wave (V) e reembasados (2 mm) com o mesmo material (L/L ou V/V) ou com as resinas para reembasamento imediato Tokuyama Rebase II (T) e Ufi Gel Hard (U). Corpos-de-prova puros de L, V, T e U (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessas resinas. Para a avaliação da adição de reforço, foi adicionado ao pó das resinas reembasadoras 5%, em massa, do reforço de floco de vidro “glass flake” (UR, TR, L/UR, L/TR, V/UR, V/TR). 320 corpos-de-prova foram confeccionados, sendo 20 para cada condição experimental. Metade desses foi submetida à ciclagem mecânica (10.000 ciclos) com freqüência de 5 Hz (LC, VC, TC, UC, URC, TRC, L/URC, L/TRC, V/URC, V/TRC). Um entalhe, em forma de V foi realizado na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto. O teste foi realizado com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) foram analisados utilizando-se ANOVA e teste de Dunnet C (α = .05). Não houve diferenças estatisticamente significantes entre as médias de resistência ao impacto das condições L, L/L, V, V/V, LC, L/LC, VC e V/VC. As condições experimentais relativas às resinas autopolimerizáveis U, T, UC, TC, UR, TR e TRC foram estatisticamente iguais entre si. Além disso, URC também foi estatisticamente igual a U, T, UC, TC, TR e TRC, porém, maior do que UR. Não houve diferença significativa (P>.05) entre as médias de resistência... / This study evaluated the effect of the addition reinforcement and cyclic loading on the resistance to impact of Charpy tests (C) and free falling-dart (FD) for the denture base resins and reline materials. To test the C, bars (60x6x2 mm) were prepared with the resins Lucitone 550 (L) and Vipi Wave (V) and relined (2 mm) with the same material (L / L or V / V) or with relining resins Tokuyama Rebase II (T) and UFI Gel Hard (U). Specimens pure of L, V, T and U (60x6x4 mm) were also made to determine the impact resistance of these resins. For the evaluation of the addition of reinforcement, was added to the powder of the relining resins 5% by weight of the glass flake glass flake (UR, TR, L / UR, L / TR, V / UR, V / TR). 320 specimens were made, 20 for each experimental condition. Half of these were subjected to cyclic loading (10,000 cycles) with a frequency of 5 Hz (LC, VC, TC, UC, URC, TRC, L / URC, L / TRC, V / URC, V / TRC). A notch in the form of V was carried out in width, the area corresponding to the relining material with depth of 0.8 mm, 3.2 mm of material remained intact. The test was conducted with pendulum of 0.5 J and 50 mm distance between the supports. The results (kJ/ m2) were analyzed using the ANOVA and Dunnet C test (α = .05). No significant differences were noted among the mean impact values of L, L / L, V, V / V, LC, L / LC, VC and V / VC. The experimental conditions for relining resins U, T, UC, TC, UR, TR and TRC were statistically equal between themselves. In addition, URC was statistically equal to U, T, UC, TC, TR and TRC, however, higher than UR. No significant differences were noted (P> .05) mong the mean impact values of L/ U, V/ U, L/ UC, V/ UC, L/URC and V/ URC. These conditions had values of resistance to impact significantly lower than those of the resin tested pure L and T (P <.05). There was... (Complete abstract click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/105513
Date20 July 2009
CreatorsPerez, Luciano Elias da Cruz [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Machado, Ana Lucia [UNESP], Canevarolo Junior, Sebastião Vicente [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format196 f. : il. color.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds