Return to search

Análise bi e tridimensional das alterações morfológicas em raízes mesiais de molares inferiores com curvaturas severas preparados por diferentes sistemas mecanizados. Estudo por microtomografia computadorizada / Bi and three-dimensional analysis of morphological alterations in mesial roots of mandibular molars with severe curvatures prepared by different mechanized systems. Computerized microtomography study

O presente estudo teve como objetivo analisar, por meio de microtomografia computadorizada, os parâmetros morfológicos das raízes mesiais de molares inferiores, preparados por três sistemas mecanizados: reciprocante (Reciproc - RC), rotatório contínuo (OneShape - OS) e reciprocante/rotatório (Twisted-File Adaptive - TFA), precedidos ou não de pré-alargamento (ProGlider - PG). Foram utilizados trinta molares inferiores, com raiz mesial apresentando ângulo (&ge;25º) e raio de curvatura (&le;2mm) severos e dois canais distintos. Por meio da técnica de amostragem estratificada, os canais foram distribuídos em seis grupos (n=10) conforme protocolo de instrumentação: G1-TFA; G2-RC; G3-OS; G4-PG + TFA; G5 - PG + RC; G6- PG + OS. Após o preparo, foram avaliados os parâmetros bidimensionais (área, perímetro, circularidade, diâmetro maior e menor) nos 5mm apicais e tridimensionais (volume, área de superfície e SMI), bem como o transporte do canal radicular. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA seguido do complementar de Tukey (&alpha;=0,05). O RC apresentou valores, significantemente, maiores de área, perímetro e diâmetro menor em relação ao TFA (p<0,001), não havendo diferença significante entre os sistemas em relação à circularidade (p=0,056) e diâmetro maior (p=0,477). O aumento do volume do canal proporcionado pelos sistemas RC e OS foram semelhantes entre si (p=0,979) e diferente estatisticamente ao TFA (p<0,001). O aumento da área de superfície promovida pelo RC foi similar ao OS (p=0,254) e diferente estatisticamente ao TFA (p=0,001), não havendo diferença entre os dois últimos sistemas (p=0,075). Os valores de SMI do grupo PG + OS foram significativamente maiores que dos demais grupos (p<0,001). Não houve diferença entre os sistemas em relação ao transporte nos terços apical e médio. Concluiu-se que todos os sistemas avaliados apresentaram alterações morfológicas bi e tridimensionais após o preparo biomecânico. O emprego do sistema ProGlider previamente aos sistemas de instrumentação não influenciou as alterações dos parâmetros avaliados. / The present study aimed to analyze, by computerized microtomography, the morphological parameters of mesial roots of mandibular molars prepared by three mechanized systems: reciprocating (Reciproc - RC), continuous rotating (OneShape - OS) and Twisted - File Adaptive (TFA), preceded or not by pre - enlargement (ProGlider-PG). Thirty teeth were used, with mesial root presenting severe angle (&ge;25º) and a radius of curvature (&le;2mm) and two distinct canals. By means of the stratified sampling technique, the canals were distributed in six groups (n = 10) according to the instrumentation protocol: G1-TFA; G2-RC; G3-OS; G4-PG + TFA; G5 - PG + RC; G6- PG + OS. After preparation, the two-dimensional parameters (area, perimeter, roundness, major and minor diameter) were evaluated in the apical 5mm as well as three-dimensional parameters (volume, surface area and SMI) and root canal transportation. The data were statistically analyzed using the ANOVA test followed by Tukey\'s complement (&alpha; = 0.05). The RC presented significantly larger values of area, perimeter, and minor diameter in relation to the TFA (p<0,001), and there was no significant difference between the systems in relation to the roundness (p=0,056) and major diameter (p=0,477). The increased canal volume provided by the RC and the OS systems were similar to each other (p=0,979) and statistically different from the TFA (p<0,001). The increase of the surface area promoted by the RC was similar to the OS (p=0,254) and statistically different to the TFA (p=0,001), with no difference between the other two systems (p=0,075). The SMI values of the PG + OS group were significantly higher than the other groups (p<0,001). There was no difference between the systems in relation to transport in the apical and middle thirds. It was concluded that all evaluated systems presented bi-dimensional and three-dimensional morphological alterations after biomechanical preparation. The use of the ProGlider system prior to the instrumentation systems did not influence the parameters evaluated.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-21052018-152619
Date19 April 2017
CreatorsFlamini, Luís Eduardo Souza
ContributorsCruz Filho, Antonio Miranda da
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguageEnglish
TypeTese de Doutorado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0022 seconds