This dissertation covers the application of heat accumulation systems in nuclear power engineering, namely in nuclear power plants. It is mainly a case of passive emergency systems, whose task is to accumulate the heat produced in the reactor’s active zone and in spent fuel pools during DBA (design-basis accidents) or beyond DBA. A particular example of heat accumulation is steam condensation after LOCA (loss of coolant accident). The primary circuit steam leakage increases containment pressure and has to be decreased by the steam condensation. This thesis deals with a theoretical substitute for ice condensers, which are used as a passive safety measure in some nuclear power plants. The substitute involves a choice of an alternative material, whose melting temperature (for heat accumulation) is closer to nuclear power plant operating temperatures. The other part of the dissertation discusses heat accumulation in spent fuel pools in case of all cooling systems failure.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:230557 |
Date | January 2013 |
Creators | Sklenářová, Lenka |
Contributors | Maar, Tomáš, Martinec, Jiří |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0016 seconds