This study aims to improve the modeling of partial SCRAM in the BISON plant model for the Forsmark 2 nuclear reactor after power uprate. Validation of the BISON model against tests performed from March to May in 2013 have shown that this is one of the areas in which there is room for improvement. After partial SCRAM is performed, the model underestimates the reactor power, recirculation flow and steam flow when compared to the measurement data. In BISON the partial SCRAM is modeled using a relative control rod effect vector (ASC vector). The aim is to replace the old values in this vector to improve the model. The new model was shown to give an improved result for the reactor power, recirculation flow and steam flow. The study gives recommendations on how to apply the new model and what values of the relative control rod effect vector that can be used in the future.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:uu-269360 |
Date | January 2015 |
Creators | Constanda, Daniel |
Publisher | Uppsala universitet, Tillämpad kärnfysik |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, info:eu-repo/semantics/bachelorThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Relation | UPTEC F, 1401-5757 ; 15069 |
Page generated in 0.0027 seconds