Return to search

Análise experimental dos efeitos do fluido e da orientação do escoamento no desempenho de dissipadores de calor baseados na ebulição convectiva em microcanais / Experimental evaluation of the effect of the fluid and the footprint orientation on the performance of a heat spreader based on flow boiling inside micro-scale channels

A pesquisa realizada envolveu a avaliação experimental dos efeitos do fluido e da orientação do escoamento no desempenho de um dissipador de calor baseado na ebulição convectiva em microcanais. Estes dissipadores de calor são usados como uma nova aplicação para a refrigeração dos novos dispositivos eletrônicos que geram altas taxas de calor. Efetuou-se inicialmente uma extensa pesquisa bibliográfica sobre o escoamento monofásico e a ebulição convectiva em microcanais e em multi-microcanais através da qual levantou-se os principais métodos de previsão do coeficiente de transferência de calor e da perda de pressão. Então, utilizando o aparato experimental desenvolvido durante o mestrado de Do Nascimento (2012) avaliou-se a transferência de calor e perda de pressão de um dissipador de calor baseado em multi-microcanais paralelos. O dissipador de calor avaliado possui 50 microcanais retangulares dispostos paralelamente com 15 mm de comprimento, 100 µm de largura, 500 µm de altura e espaçados de 200 µm. Ensaios experimentais foram executados para o R245fa, fluido de baixa pressão utilizado em ciclos frigoríficos de baixa pressão, e R407C, fluido de alta pressão usado para conforto térmico, temperatura de saturação de 25 e 31°C, velocidades mássicas de 400 a 1500 kg/m²s, graus de subresfriamento do líquido de 5, 10 e 15°C, título de vapor máximo de até 0,38, fluxos de calor de até 350 kW/m², e para 3 orientações diferentes do dissipador de calor, horizontal, vertical com os canais alinhados horizontalmente e vertical com escoamento ascendente. Os resultados obtidos foram parametricamente analisados e comparados com métodos da literatura. Coeficientes de transferência de calor médios de até 35 kW/m² °C foram obtidos. Resultados adquiridos para o R245fa e R407C foram inferiores aos levantados por Do Nascimento (2012) para o R134a utilizando o mesmo dissipador. O fluido R407C apresentou frequências e amplitudes de oscilações inferiores aos fluidos R134a e R245fa. Nenhum método para o coeficiente de transferência de calor e perda de pressão proporcionou previsões satisfatórias dos dados experimentais. O modelo Homogêneo com viscosidade da mistura bifásica dada por Cicchitti et al. (1960) apresentou as melhores previsões da perda de pressão, já para o coeficiente de transferência de calor, os métodos de Bertsch et al. (2009) e Liu e Winterton (1991) apresentaram as melhores previsões. O dissipador com sua base posicionada horizontalmente fornece coeficientes de transferência de calor superiores enquanto sua base na vertical e escoamento ascendente verificam-se perdas de pressão inferiores. Imagens do escoamento bifásico foram obtidas com uma câmera de alta velocidade e analisadas. / This study presents an experimental investigation on the effect of the fluid and the footprint orientation on the performance of a heat spreader based on flow boiling inside micro-scale channels. This heat spreader is used in an electronics cooling application with high-power density. Initially an extensive investigation of the literature concerning single-phase and two-phase flow inside a single microchannels and multi-microchannels was performed. In this literature review the leading predictive methods for heat transfer coefficient and pressure drop are described. The experimental study was carried out in the apparatus developed by Do Nascimento (2012). The heat sink evaluated in the present study is comprised of fifty parallel rectangular microchannels with cross-sectional dimensions of 100 µm width and of 500 µm depth, and total length of 15 mm. The fins between consecutive microchannels are 200 µm thick. Experimental tests were performed for R245fa, low-pressure fluid used in low pressure refrigeration cycles, and R407C, high-pressure fluid used for heat comfort, saturation temperature of 25 and 31°C, mass velocities from 400 to 1500 kg/m² s, degrees of subcooling of the liquid of 5, 10 and 15°C, outlet vapor quality up to 0.38, heat fluxes up to 350 kW/m², and for the following footprint heat sink orientations: horizontal, vertical with the microchannels aligned horizontally and vertical with upward flow. The results were parametrically analyzed and compared again the predictive methods from literature. Average heat transfer coefficients up to 35 kW/m² °C were obtained. The results for R134a from Do Nascimento (2012) for the same heat sink presented heat transfer coefficients higher than R245fa and R407C. The fluid R407C presented oscillation of the temperature due to thermal instability effects with lower frequency and amplitude lower than R134a, and R245fa. None predictive method provided satisfactory heat transfer coefficient and pressure drop predictions of the experimental data. The Homogeneous model with the viscosity given by Cicchitti et al. (1960) provided the best pressure drop prediction while the heat transfer coefficient was best predicted by Bertsch et al. (2009) and Liu and Winterton (1991). The horizontal orientation of the footprint provided the highest heat transfer coefficients while the vertical footprint orientation with upward flow the lowest pressure drops. Images of the two-phase flow were obtained with a high-speed camera and analyzed.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-19082014-102054
Date06 February 2014
CreatorsHugo Leonardo Souza Lara Leão
ContributorsGherhardt Ribatski, Christian Johann Losso Hermes, Luciana Wasnievski da Silva de Luca Ramos
PublisherUniversidade de São Paulo, Engenharia Mecânica, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds