Return to search

Correla??es entre resultados de ensaios SPT e CPT para solo arenoso sedimentar / Coorelations between SPT and CPT test results for a sedmientary sandy soil

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-02-22T18:37:41Z
No. of bitstreams: 1
EmanuelErivanSilvaDaCunha_DISSERT.pdf: 3171169 bytes, checksum: 22dfdf808d39c79005e38c047376f691 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-03-03T23:53:31Z (GMT) No. of bitstreams: 1
EmanuelErivanSilvaDaCunha_DISSERT.pdf: 3171169 bytes, checksum: 22dfdf808d39c79005e38c047376f691 (MD5) / Made available in DSpace on 2017-03-03T23:53:31Z (GMT). No. of bitstreams: 1
EmanuelErivanSilvaDaCunha_DISSERT.pdf: 3171169 bytes, checksum: 22dfdf808d39c79005e38c047376f691 (MD5)
Previous issue date: 2016-05-30 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / O ensaio SPT ? a ferramenta mais utilizada no Brasil para a obten??o de par?metros geot?cnicos para elabora??o de projetos de funda??o. Em contrapartida o CPTu ainda ? pouco usual, fato explicado pelo pequeno n?mero de empresas que o executam e pelo custo elevado. Logo, ? justificada a busca por correla??es para estimativa de par?metros do ensaio CPTu atrav?s de dados do ensaio SPT. No entanto a grande maioria dos estudos realizados concentram-se no sul e sudeste do pa?s, refor?ando a necessidade da determina??o de correla??es em outras regi?es, considerando as caracter?sticas dos solos locais. O objetivo desse trabalho ? determinar correla??es entre a resist?ncia a penetra??o do ensaio SPT (????) com a resist?ncia de ponta (??) e a resist?ncia lateral (fs) do ensaio CPTu. Utilizando-se ajustes lineares e uma abordagem geoestat?stica simplificada, obtiveram-se correla??es entre 88 sondagens SPT e oito ensaios CPTu para profundidades m?ximas de 22 m, em um dep?sito de areia siltosa na Cidade de Natal, no nordeste do Brasil. Os valores de NSPT utilizados nas correla??es foram corrigidos para energia padr?o internacional de 60%. A sele??o dos dados utilizou crit?rios geoestat?sticos, atrav?s do alcance do variograma para demarca??o da zona de influ?ncia das sondagens, bem como aplica??o de m?todos como IDW e Krigagem ordin?ria. / The standard penetration test (SPT) is the most commonly used in situ test for obtaining the required geotechnical parameters for foundation analysis and design in Brazil. Since in most situations only SPT data is available, the search for new SPT-CPT correlations is necessary. However, most of the available SPT-CPT correlations in Brazil have been established for soils of southern regions of the country. New local correlations for other soil types are therefore necessary. This study aims at determining correlations between the SPT resistance number (NSPT), and the CPT tip resistance (qc) and sleeve friction resistance (fs) for a silty sand deposit at the city of Natal, at the Northeast coast of Brazil. Using linear fittings and a simplified geostatistic approach, correlations were obtained for 88 SPT boreholes and eight CPT boreholes. The NSPT blowcount values where corrected for the energy of 60%. SPT-CPT correlations were devised using the following approaches: variogram analysis, inverse distance weighting (IDW) and ordinary kriging.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/22135
Date30 May 2016
CreatorsCunha, Emanuel Erivan Silva da
Contributors92610927487, http://lattes.cnpq.br/6737841388506901, Costa, Carina Maia Lins, 82818819415, http://lattes.cnpq.br/6483888857335060, Aoki, Nelson, 00942251768, http://lattes.cnpq.br/1932648220564260, Bezerra, Jonh Eloi, Costa, Yuri Daniel Jatob?
PublisherPROGRAMA DE P?S-GRADUA??O EM ENGENHARIA CIVIL, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0301 seconds