Subkanálová analýza aktivní zóny jaderného reaktoru VVER-1000 / Subchannel analysis of VVER-100 reactor core

This master’s thesis deals with boiling crisis and with departure from nucleate boiling ratio. This thesis explains terms like the boiling crisis in nuclear reactors and the thesis deals with individual parameters of the reactor core, which have an impact on departure from nucleate boiling ratio. After that, the thesis deals with subchannel analysis and describes basic mathematical and physical models of the chosen subchannel program. The thesis then processes, with the ALTHAMC12 subchannel program, the chosen parameters and their impact on departure from nucleate boiling ratio. The conclusion of the diploma thesis deals with the evaluation of the best and worst calculated combination.