Return to search

Field Current Control for the Damping of Rotor Oscillations and for the Alternative Start of Synchronous Machines : Further Innovative Applications of Field Current Active Control besides UMP-Compensation

The possibility to save energy in synchronous machines operation by dismissing d-axis damping bars and surrogating them with active excitation current control in sectored field winding is proved. In particular a way to recover the energy of rotor oscillations during power regulation is shown by means of a studycase generator whereas a self-starting machine is analytically and numerically designed in view of its next construction and test. Principal design requirements and limits for both applications are presented and discussed.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:uu-353669
Date January 2018
CreatorsFelicetti, Roberto
PublisherUppsala universitet, Institutionen för teknikvetenskaper
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess
RelationUppsala Dissertations from the Faculty of Science and Technology, 1104-2516, TVE-MFE ; 18004