Return to search

Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata

Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-02-03Bitstream added on 2014-06-13T19:43:11Z : No. of bitstreams: 1
vasconcelos_lw_dr_araca.pdf: 3387652 bytes, checksum: 665ddeee618bbda24e7caff661ab090e (MD5) / Universidade Estadual Paulista (UNESP) / Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação... / Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants’ stability.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/103321
Date03 February 2005
CreatorsVasconcelos, Laércio Wonhrath [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Carvalho, Paulo Sérgio Perri de [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format140 f. : il. + 1 CD-ROM
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0025 seconds