Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-06-07T17:48:34Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Estudo clínico randomizado da eficiência de cimentos de ionômero de vidro no controle da hipersensibilidade dentinária.pdf: 1005124 bytes, checksum: 267a83e1e44844abaa1b52b31935bb52 (MD5) / Made available in DSpace on 2017-06-07T17:48:34Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Estudo clínico randomizado da eficiência de cimentos de ionômero de vidro no controle da hipersensibilidade dentinária.pdf: 1005124 bytes, checksum: 267a83e1e44844abaa1b52b31935bb52 (MD5)
Previous issue date: 2014-04-23 / Sem bolsa / A hipersensibilidade dentinária é caracterizada como uma reação dolorosa da dentina exposta a estímulos não-nocivos de natureza química, térmica, tátil ou osmótica. Entre os tratamentos, o cimento de ionômero de vidro atua na redução da dor através da obliteração dos túbulos dentinários. O objetivo desse estudo clínico randomizado, duplo-cego e de boca-dividida foi avaliar a eficiência no controle da hipersensibilidade de um cimento de ionômero de vidro modificado por resina, Clinpro XT® (3M Espe, Minnesota, EUA), e um ionômero de vidro convencional, Vidrion R® (SS White, Gloucester, Reino Unido). Como critérios de inclusão, os pacientes deveriam ter pelo menos 2 dentes em diferentes hemi-arcos apresentando o problema. Vinte pacientes, perfazendo 152 dentes com hipersensibilidade, foram aleatoriamente divididos em dois grupos de intervenção. Em um hemi-arco foi
aplicado o Clinpro XT, e no outro o tratamento convencional com Vidrion R. Previamente ao tratamento (baseline), a sensibilidade dolorosa foi avaliada por teste tátil e evaporativo utilizando a Escala Visual Analógica (EVA). Após a aplicação, avaliações periódicas foram feitas nos seguintes intervalos: 5 minutos; 7, 14, 21, 30, 90 e 180 dias. A análise estatística foi feita utilizando os métodos não-paramétricos de Kruskal-Wallis, Friedman para comparações entre tempos para cada material e Mann-Whitney para comparação entre os materiais utilizados (a=5%). Para ambos os testes tátil e evaporativo houve diminuição significativa da dor imediatamente
após aplicação dos produtos (5 min). Após a aplicação dos materiais os valores das medianas foram estatisticamente inferiores aos valores do baseline durante os 6 meses de acompanhamento (p<0.05). Contudo, em 180 dias de acompanhamento nenhuma diferença estatística significante foi observada entre os dois tipos de iônomeros frente aos estímulos testados. Ambos os materiais, Clinpro XT e Vidrion R, demonstraram efeitos significativos na redução da hipersensibilidade nos 6 meses de avaliação clínica. / Dentin hypersensitivity is characterized as a painful reaction of exposed dentine to chemical, thermal, tactile or osmotic non-harmful stimulus. Among treatments, the glass ionomer cement acts in reducing pain through the obliteration of dentinal tubules. The aim of this randomized, double-blind and split-mouth clinical trial was to evaluate and compare the desensitizing efficacy of a resin modified glass ionomer cement, Clinpro XT® (3M Espe, Minnesota, USA), and a conventional glass ionomer cement, Vidrion R® (SS White, Gloucester, UK), at 6-months follow-up. Subjects should have at least two teeth in different hemiarchs with dentin hypersensitivity.
Twenty patients with 152 hypersensitive teeth were randomly divided into two intervention groups. One group received the Clinpro XT and the other conventional glass ionomer cement Vidrion R. Prior to the desensitizing treatment, painful symptoms were assessed by tactile and air blast tests using the Visual Analogue Scale (VAS). Re-evaluations of the treatments occurred after 5 minutes; 7, 15, 21, 30, 90 and 180 days. The statistical analysis was performed using the Kruskal-Wallis,
Friedman and Mann-Whitney analysis (a=5%). In both tests (tactile and air blast) there was significant reduction of painful symptoms immediately after application of materials (5 min). The median values of VAS score were statistically lower than baseline values during the 6-month follow-up (p<0,05). Besides, no significant differences were observed between the two types of glass ionomer cements evaluated with tactile and air blast test in all evaluation periods. Clinpro XT and Vidrion R demonstrated significant effects in reducing dentin hypersensitivity at 6- months follow-up.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpel.edu.br:prefix/3491 |
Date | 23 April 2014 |
Creators | Madruga, Marina de Matos |
Contributors | 95219668072, http://lattes.cnpq.br/0022372882780892, Silva, Adriana Fernandes da, Lund, Rafael Guerra |
Publisher | Universidade Federal de Pelotas, Programa de Pós-Graduação em Odontologia, UFPel, Brasil, Faculdade de Odontologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPEL, instname:Universidade Federal de Pelotas, instacron:UFPEL |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0018 seconds