Return to search

Desenvolvimento de uma metodologia analítica para determinação de ácidos fenólicos em amostras de azeite de dendê (Elaeis guineensis) por HPLC com detecção simultânea no UV e eletroquímica (homemade)

Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-17T11:46:34Z
No. of bitstreams: 1
rafaelasilvalamarca.pdf: 2422143 bytes, checksum: 5faa827f8d908eb13b61ec3fb1c1fd93 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-28T13:39:59Z (GMT) No. of bitstreams: 1
rafaelasilvalamarca.pdf: 2422143 bytes, checksum: 5faa827f8d908eb13b61ec3fb1c1fd93 (MD5) / Made available in DSpace on 2016-06-28T13:40:00Z (GMT). No. of bitstreams: 1
rafaelasilvalamarca.pdf: 2422143 bytes, checksum: 5faa827f8d908eb13b61ec3fb1c1fd93 (MD5)
Previous issue date: 2015-09-25 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As substâncias fenólicas têm se tornado objeto de investigação, devido aos inúmeros benefícios à saúde humana e a influência na qualidade alimentícia. Neste trabalho determinou-se os ácidos fenólicos presentes no azeite de dendê, de fabricação artesanal e industrializado. Para estas análises utilizou-se um cromatógrafo líquido de alta eficiência (HPLC Agilent 1100 series), injetor manual com válvula Rheodyne de 20μL, coluna de fase Reversa C18 Inertsil ODS-3, coluna de guarda Inertsil ODS, detector UV-VIS de múltiplos comprimentos de ondas (UV-VIS MWD). Ao canal de resíduos do HPLC foi adaptada uma célula eletroquímica, com capacidade de 1,00 mL, sendo esta composta por três eletrodos: eletrodo de trabalho, carbono vítreo; eletrodo de referência, Ag/AgCl (KCl,sat) e eletrodo auxiliar de aço inox. As medidas eletroquímicas foram realizadas em um potenciostato μAutolab type III, conectado a um microcomputador, utilizando o software GPES 4.9. As análises foram realizadas de forma simultânea em ambos detectores, em uma mesma injeção. A fase móvel otimizada foi capaz de separar os analitos totalmente, sendo esta composta pela mistura uma solução aquosa de H3PO4 pH 2,40 + NaClO4 a 7 mmol.L-1/isopropanol (87:13 v/v), por eluição isocrática. O comprimento de onda utilizado na detecção UV foi 225 nm. As medidas amperométricas foram realizadas no potencial de +1,1 V para todos os analitos. A recuperação das amostras foi realizada através da padronização interna, utilizando o ácido o-cumárico como padrão interno (PI) e o ácido m-cumárico como padrão surrogate (PS). A recuperação do PS foi superior a 75% em ambos detectores para todas as amostras. Os limites instrumentais para detecção UV variaram de 0,019 (ácido siríngico) a 0,029 mg.L-1 (ácido ferúlico) e de quantificação 0,063 (ácido siríngico) a 0,095 mg.L-1 (ácido sinápico); já para a detecção eletroquímica (DE) os limites de detecção encontraram-se na faixa de 0,015 (ácido p-cumárico) a 0,079 mg.L-1(ácido ferúlico) e os de quantificação 0,050 (ácido p-cumárico) a 0,27 mg.L-1(ácido ferúlico). As concentrações dos ácidos fenólicos nas amostras de azeite de dendê de fabricação artesanal, variaram de 0,12 a 10,3 mg.L-1 (detecção UV) e de 1,0 a 11,0 mg.L-1 (DE). Já as concentrações obtidas nas amostras de azeite de dendê industrializadas variaram de 0,21 a 14,7 mg.L-1 (detecção UV) e de 3,0 a 11,9 mg.L-1 (DE). O sistema HPLC-UV-DE mostrou-se promissor nas análises dos ácidos fenólicos nestas e em outras matrizes complexas. / Phenolic substances have become the subject of investigation due to the numerous benefits to human health and the influence in the food quality. In this work, the phenolic acids in homemade and industrialized palm oil were determined. For these analyzes, it was used a high performance liquid chromatograph (HPLC Agilent 1100 series) with a manual 20μL Rheodyne valve, a reverse phase column C18 Inertsil ODS-3, a guard column Inertsil ODS and a UV-VIS detector for multiple wavelengths (UV-VIS MWD). At the end of HPLC waste channel was adapted an electrochemical cell with a capacity of 1.00 mL, with a standard three-electrode configuration, consisting of glassy carbon working electrode, a Ag/AgCl (KCl, sat) reference electrode and stainless steel needle as counter electrode. The electrochemical measurements were made using a μAutolab type III potentiostat, with its data acquisition software (GPES 4.9 version). The detections were performed sequentially, in the same injection. The optimal mobile phase was able to completely separate the analytes by isocratic elution, being composed of an aqueous solution of H3PO4 pH 2.40, containing 7mmol.L-1 of NaClO4 /isopropanol (87:13 v/v). The wavelength used for the UV detection was 225 nm. The amperometric measurements were performed at +1.1 V for all analytes. The recovery of the samples was performed using internal standardization, using o-coumaric acid as internal standard (PI) and m-coumaric acid as standard surrogate (PS). The recovery of PS was over 75% on both detectors for all samples. The instrumental limits for UV detection ranged from 0.019 (syringic acid) to 0.029 mg L-1 (ferulic acid) and quantification limits from 0.063 (syringic acid) to 0.095 mg L-1 (sinapic acid). In the same way, for electrochemical detection (ED) the instrumental limits was found in the range of 0.015 (p-coumaric acid) at 0.079 mg L-1 (ferulic acid), and the quantification limits were between 0.050 (p-coumaric acid) and 0.27 mg L-1 (ferulic acid). The concentration of phenolic acids in homemade palm oil samples ranged from 0.12 to 10.3 mg L-1 (UV detection) and from 1.0 to 11.0 mg L-1 (ED). The concentrations obtained in the industrialized palm oil samples varied from 0.21 to 14.7 mg L-1 (UV detection) and from 3.0 to 11.9 mg L-1 (ED). The HPLC-UV-ED system has shown promise in the analysis of these phenolic acids in this and other complex matrices.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/1552
Date25 September 2015
CreatorsLamarca, Rafaela Silva
ContributorsMatos, Maria Auxiliadora Costa, Franchini, Romulo Augusto de Abreu, Lowinsohn, Denise
PublisherUniversidade Federal de Juiz de Fora, Programa de Pós-graduação em Química, UFJF, Brasil, ICE – Instituto de Ciências Exatas
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds