Return to search

Desenvolvimento e implementação de gerador de surto e sua aplicação na análise numérico-experimental do comportamento transitório de sistemas de aterramento.

Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-10T18:57:29Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-14T15:02:21Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) / Made available in DSpace on 2017-02-14T15:02:21Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5)
Previous issue date: 2015-09-21 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, são apresentadas em detalhes, as etapas do projeto e construção de um gerador de surto de tensão com base em normas internacionalmente estabelecidas (IEC 61000-4-5). Os dois sinais de saída implementados possuem formas de onda características de surtos devidos às descargas atmosféricas primeira e subsequente, respectivamente. Ainda, seus parâmetros obedecem aos valores padronizados pelas normas IEC 60060-1 e IEEE Std-4. A fim de validar o gerador de surto construído, foram analisados os comportamentos transitório e estacionário de diversos sistemas de aterramento quando submetidos a descargas atmosféricas, utilizando o referido gerador como fonte do sinal de injeção. Os sistemas de aterramento foram analisados mediante experimentos em campo, sendo que cada experimento foi reproduzido numericamente através do método FDTD. Baixos erros percentuais foram obtidos entre os sinais medidos durante os experimentos e os sinais numéricos correspondentes. Isso, aliado ao fato de que os aterramentos analisados se comportaram conforme o esperado na literatura, valida o gerador de surto construído neste trabalho. / In this work, the design and construction steps of a voltage surge generator are detailed based on established international standards (IEC 61000-4-5). The waveforms of the two output signals implemented are representative of surges due to the first and subsequent lightning strokes, respectively. Also, their parameters meet the requirements imposed by the standards IEC 60060-1 and IEEE Std-4. In order to validate the surge generator, it was analyzed the transient and steady-state behaviors of several grounding systems when subjected to lightning strokes, using the developed generator as the source of the injection signal. The grounding systems were analyzed by field experiments, and each experiment was reproduced numerically using the FDTD method. Low percentage errors were obtained between the signals measured during the field experiments and the corresponding numerical signals. Moreover, the analyzed grounding systems behaved as expected in literature. Those two facts validade the surge generator built in this work.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/7676
Date21 September 2015
CreatorsARAÚJO, Ramon Cristian Fernandes
ContributorsOLIVEIRA, Rodrigo Melo e Silva de
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds