Return to search

Análise da aplicabilidade de sensores de acoplamento capacitivo no monitoramento de disjuntores de alta tensão.

Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-17T13:51:49Z
No. of bitstreams: 1
HENRIQUE NUNES DE SANTANA – DISSERTAÇÃO (PPGEE) 2017.pdf: 2930914 bytes, checksum: a4c0e297d62f2854c085762512fb6f16 (MD5) / Made available in DSpace on 2018-04-17T13:51:49Z (GMT). No. of bitstreams: 1
HENRIQUE NUNES DE SANTANA – DISSERTAÇÃO (PPGEE) 2017.pdf: 2930914 bytes, checksum: a4c0e297d62f2854c085762512fb6f16 (MD5)
Previous issue date: 2017-08-18 / Capes / Neste trabalho, é avaliada aplicabilidade de sensores de acoplamento capacitivo na detecção dos sinais emitidos por arcos elétricos em contatos de disjuntores. Adicionalmente, é investigada a possibilidade de correlacionar estes sinais com nível de degradação dos contatos de arco. A aplicabilidade dos sensores é avaliada por meio da comparação dos sinais detectados pelos mesmos, com os sinais detectados por uma antena direcional em banda larga, tanto no domínio do tempo quanto no domínio da frequência. Para a análise da correlação entre o nível de degradação dos contatos de arco e os sinais detectados, atributos de estatística descritiva da duração e da energia dos sinais foram avaliados. A análise dos resultados evidenciou que os sensores de acoplamento capacitivo são capazes de detectar os sinais emitidos pelos arcos elétricos. Também foi evidenciado que a sensibilidade de detecção dos sensores depende da posição na qual foram instalados ao longo do polo analisado. No caso dos disjuntores utilizados neste trabalho, a melhor posição para a instalação dos sensores foi a posição mais próxima do terminal inferior do polo. A flexibilidade e o valor da constante dielétrica devem ser avaliados no momento da escolha do material empregado na confecção dos sensores, uma vez que sensores pouco flexíveis podem sofrer danos ao serem instalados no polo do disjuntor e, constantes dielétricas elevadas podem prejudicar os ganhos dos respectivos sensores. A correlação entre os sinais dos arcos elétricos detectados pelos sensores e o nível de degradação dos contatos de arco é possível, quando os atributos estatísticos da média, desvio padrão, curtose e mediana obtidos da energia dos referidos sinais são avaliados. / In this work, is evaluated the applicability of capacitive coupling sensors in the detection of signals emitted by electric arcs in circuit breaker contacts. In addition, the possibility of correlating these signals with the arcing contacts degradation level is investigated. The sensors applicability is investigated by comparing the signals detected by them with the signals detected by a broadband directional antenna in both time and frequency domain. For the analysis of the correlation between the arcing contacts degradation level and the detected signals, descriptive statistical attributes of the duration and energy of the signals were evaluated. The analysis of the results showed that the capacitive coupling sensors are able to detect the signals emitted by the electric arcs. It was also evidenced that the sensor detection sensitivity depends on the position in which they are installed along the analyzed pole. In the case of the circuit breakers used in this work, the best position for the installation of the sensors was the one closest to the lower terminal of the pole. The flexibility and value of the dielectric constant must be evaluated when choosing the material used in the construction of the sensors, since weak sensors can be damaged when installed at the pole of the circuit breaker, and high dielectric constants can affect the gains of the respective sensors. The correlation between the electric arcs signals detected by the sensors and the arcing contacts degradation level is possible, when the statistical attributes of the mean, standard deviation, kurtosis and median obtained from the energy of these signals are evaluated.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/403
Date17 April 2018
CreatorsSANTANA, Henrique Nunes de.
ContributorsCOSTA, Edson Guedes da., NEVES, Washington Luiz Araújo., FERREIRA, Tarso Vilela., ALBERT, Bruno Barbosa.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess
RelationCOPELE

Page generated in 0.0024 seconds