Avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy e LiF:Mg, Ti na dosimetria de feixes clínicos de elétrons / ASSESSMENT OF CaSO4:Dy AND LiF:Mg,Ti THERMOLUMINESCENT DOSIMETERS PERFORMANCE IN THE DOSIMETRY OF CLINICAL ELECTRON BEAM

A avaliação do desempenho dos detectores termoluminescentes de CaSO4:Dy, produzidos pelo IPEN, tem como objetivo apresentar uma alternativa aos dosímetros de LiF:Mg,Ti comerciais (TLD-100), amplamente empregados em radioterapia, na dosimetria de feixes clínicos de elétrons. Os dois tipos de detectores termoluminescentes foram caracterizados, com a utilização de objetos simuladores de PMMA, água sólida do tipo RMI-457 e água, em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV de energias nominais, nos quais as curvas de dose-resposta foram obtidas e as doses superficial e profunda foram determinadas. A dependência da resposta termoluminescente com a energia nominal dos elétrons e com o objeto simulador empregado foram estudadas. O CaSO4:Dy apresentou o mesmo comportamento do LiF:Mg,Ti; de maneira que sua aplicação como uma alternativa às pastilhas TLD-100 na dosimetria de feixes de elétrons em radioterapia é viável e apresenta a sensibilidade à radiação de elétrons significativamente mais alta como principal vantagem. / The assessment of the performance of CaSO4:Dy thermoluminescent detectors produced by IPEN in the dosimetry of clinical electron beams aims to propose an alternative to the LiF:Mg,Ti commercial dosimeters (TLD-100) largely applied in radiation therapy. The two types of thermoluminescent dosimeters were characterised with the use of PMMA, RMI-457 type solid water and water phantoms in radiation fields of 4, 6, 9, 12 and 16 MeV electrons of nominal energies in which the dose-response curves were obtained and the surface and depth doses were determined. The thermoluminescent response dependency with the electron nominal energies and the applied phantom were studied. The CaSO4:Dy presented the same behaviour than the LiF:Mg,Ti in such a way that its application as an alternative to the TLD-100 pellets in the radiation therapy dosimetry of electron beams is viable and presents the significantly higher sensitivity to the electron radiation as its main advantage.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-08092009-165036
Date12 May 2008
CreatorsNunes, Maíra Goes
ContributorsRodrigues, Letícia Lucente Campos
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguageEnglish
TypeDissertação de Mestrado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0017 seconds