Orientador: Paulo Sérgio Flores Campos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T21:46:21Z (GMT). No. of bitstreams: 1
Neves_FredericoSampaio_D.pdf: 1442261 bytes, checksum: c45a8c982a306e84e96e0e626c50d60c (MD5)
Previous issue date: 2013 / Resumo: O objetivo no presente estudo foi avaliar a influência dos tipos de escaneamento da tomografia computadorizada de feixe cônico (TCFC) no diagnóstico de fraturas radiculares e na qualidade da imagem na presença de diferentes materiais intracanal. A amostra foi composta por trinta dentes unirradiculares divididos em três grupos (n=10): controle, fratura radicular completa e incompleta. Em cada dente foram utilizados diferentes materiais intracanal (guta-percha, pino metálico e pino de fibra de vidro), bem como a ausência de material intracanal. Cada dente foi escaneado no tomógrafo 3D Accuitomo 170 utilizando-se quatro diferentes tipos de escaneamentos (High-Resolution, High-Fidelity, Hi-Speed e Standard). Adicionalmente, os valores de produto dose área foram calculados em cada tipo de escaneamento da TCFC. As imagens foram avaliadas aleatoriamente por cinco radiologistas odontológicos. Observou-se que fraturas radiculares completas foram mais facilmente visualizadas do que as incompletas. A presença do pino metálico e da guta-percha influenciaram negativamente no diagnóstico de fratura radicular. Em relação aos tipos de escaneamento da TCFC, não houve influência no diagnóstico de fratura radicular completa. Para os casos de fratura radicular incompleta, os protocolos High-Fidelity, High-Resolution e Standard obtiveram uma maior acurácia de diagnóstico, especialmente nos grupos pino de fibra de vidro e sem preenchimento. Pôde-se concluir que os tipos de escaneamento da TCFC influenciaram pouco no diagnóstico de fraturas radiculares, sendo que a presença de materiais intracanal apresentou um maior impacto em seu diagnóstico / Abstract: The aim of this study was to evaluate the influence of cone beam computed tomography (CBCT) imaging modes in the diagnosis of root fractures as well as in subjective image quality with different intracanal materials. The sample consisted of thirty single-rooted teeth divided in three grupous (n=10): control, complete and incomplete root fracture. In each tooth different materials used were used (gutta-percha, metal post and fiber post), as well as the no filling material. Each tooth/root was scanned in a 3D Accuitomo 170 CBCT device using four different imaging modes (High-Resolution, HighFidelity, High-Speed and Standard). Additionally, the dose-area product was calculated for each CBCT imaging mode. The images were randomly evaluated by five dentomaxillofacial radiologists. Complete root fractures were visualized more easily than incomplete fractures. The presence of metal post and gutta-percha influenced negatively the diagnosis of root fracture. Regarding the CBCT imaging modes, there was no influence for complete root fracture diagnosis. In cases of incomplete root fractures, High-Fidelity, High-Resolution and Standard had a higher diagnostic accuracy, especially in the fiber post and no filling groups. In conclusion, the CBCT imaging modes had little influence in the diagnosis of complete and incomplete root fractures, while the presence of intracanal material had greater impact in the diagnosis / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288462 |
Date | 23 August 2018 |
Creators | Neves, Frederico Sampaio, 1984- |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Campos, Paulo Sérgio Flores, Vaz, Sergio Lins de Azevedo, Rebello, Ièda Margarida Crusoé Rocha, França, Deborah Queiroz de Freitas, Haiter Neto, Francisco |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 90 f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.008 seconds