Return to search

Impacto da proteção do tipo crowbar dos aerogeradores de indução duplamente excitados nos sistemas de proteção de redes de distribuição

Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-21T18:40:07Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoProtecaoTipo.pdf: 1575069 bytes, checksum: a2fcaa26dea5129a1846694b720486fe (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-27T13:52:13Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoProtecaoTipo.pdf: 1575069 bytes, checksum: a2fcaa26dea5129a1846694b720486fe (MD5) / Made available in DSpace on 2017-03-27T13:52:13Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoProtecaoTipo.pdf: 1575069 bytes, checksum: a2fcaa26dea5129a1846694b720486fe (MD5)
Previous issue date: 2016-04-07 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A contínua incorporação de geração distribuída às redes de energia elétrica no mundo, a partir de fontes renováveis, tem contribuído positivamente no fornecimento de energia, na eficiência energética e na redução de gases poluentes. Apesar disso, novos desafios relacionados com as mudanças na qualidade da energia, a estabilidade do sistema e os níveis de curto circuito, dentre outros, continuam sendo alvo de pesquisas. O Brasil tem adicionado nos últimos anos uma importante quantidade de gigawatts às redes graças a conexão de grandes parques eólicos. Adicionalmente, as recentes possibilidades para que os consumidores se tornem pequenos geradores e troquem energia nas redes de distribuição, visa a conexão de outra quantidade de gigawatts. Diante disto, este trabalho apresenta as análises do impacto da atuação da proteção do tipo crowbar dos aerogeradores de indução duplamente excitados (DFIG) sobre os sistemas de proteção empregados nas redes de distribuição radiais, visando avaliar a influência que exerce sobre a coordenação das funções de proteção de sobrecorrente quando ocorrem faltas na rede. Para garantir este objetivo, avaliações das contribuições às correntes de curto-circuito do DFIGs ligados à rede durante perturbação, são efetuadas no software DIGSILENT Power Factory 14.1, sob a consideração de dois casos de operação do DFIG. Um deles contempla a não inserção da proteção do tipo crowbar e o outro considera a inserção desta proteção durante uma perturbação na rede. A estratégia para implantar a proteção do tipo crowbar estabelece a inserção de resistências ao circuito do rotor do DFIG quando forem ultrapassados limites de corrente no rotor e tensão no ponto de conexão. Os resultados obtidos fornecem informações relevantes relacionadas com as mudanças nos níveis de curto-circuito, as quais devem ser contempladas nos estudos prévios à conexão de novos DFIG, devido a importância que representam para coordenar as funções de proteção de sobreccorrente sob considerações dinâmicas e em regime permanente. / The continued incorporation of distributed generation from renewable sources to electricity networks in the world, has contributed positively in the energy supply, energy efficiency and reduction of polluting gases. Nevertheless, new challenges related to the variations in power quality, system stability, short circuit levels, among others, continue to be research. The Brazil has added in recent years an important amount of gigawatts to networks through the connection of large wind farms. In addition, recent possibilities for consumers to make small generators and exchange energy in the distribution network aims to connect another quantity of gigawatts. In this context, this work presents the analysis of the impact of Crowbar protection of double feed induction generator (DFIG) on protection systems used in radial distribution networks to evaluate its influence on the coordination of overcurrent protection functions when there are faults in the network. To reach this goal, assessments of contributions to short-circuit currents of DFIG connected to the grid during disturbance, was simulated in DIGSILENT Power Factory 14.1 software where two cases where considered. The first includes the non-inclusion of crowbar protection and the second considers the inclusion of this protection during a network disturbance. The strategy implemented on crowbar protection proposed the series resistance insertion in the rotor circuit when thresholds velocity, current in the rotor and voltage at the connection point, are Exceeded. The results provide relevant short-circuit levels information that from now on must be considered during previous DFIG connection studies due to the importance they represent to coordinate overcurrent protection function under dynamic and steady state conditions.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/8006
Date07 April 2016
CreatorsARIAS, Piedy Del Mar Agamez
ContributorsNUNES, Marcus Vinícius Alves
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds