O desempenho da compartimenta??o horizontal seletiva na promo??o da seguran?a contra inc?ndio em edifica??es

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-08-09T22:49:24Z
No. of bitstreams: 1
LeonardoJorgeBrasilDeFreitasCunha_TESE.pdf: 18700119 bytes, checksum: 099db9a5955fbcce2aa9a2d7d78f62fd (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-08-10T22:57:29Z (GMT) No. of bitstreams: 1
LeonardoJorgeBrasilDeFreitasCunha_TESE.pdf: 18700119 bytes, checksum: 099db9a5955fbcce2aa9a2d7d78f62fd (MD5) / Made available in DSpace on 2016-08-10T22:57:29Z (GMT). No. of bitstreams: 1
LeonardoJorgeBrasilDeFreitasCunha_TESE.pdf: 18700119 bytes, checksum: 099db9a5955fbcce2aa9a2d7d78f62fd (MD5)
Previous issue date: 2016-04-12 / No trabalho apresentam-se os resultados da pesquisa que aborda o desempenho da compartimenta??o horizontal seletiva na promo??o da Seguran?a Contra Inc?ndio em Edifica??es - SCIE. A compartimenta??o horizontal ? uma medida de prote??o passiva de total controle por parte do arquiteto, pass?vel de ser definida logo nas primeiras fases do processo projetual. Contudo, nota-se uma cont?nua reconfigura??o dos ambientes em edifica??es acad?micas, objetivando ajust?-los ? demanda surgente por espa?o. Assim, um determinado ambiente concebido inicialmente como uma ampla sala de aula pode se transformar em duas ou mais salas menores, por exemplo. Independentemente do momento em que ocorre a subdivis?o, seja na fase de projeto ou durante a ocupa??o da edifica??o, as normas s? consideram o ambiente compartimentado quando s?o empregados os elementos classificados como corta-fogo. Entretanto, considerando que os minutos iniciais de um inc?ndio s?o os mais importantes na prote??o a vida, trabalhou-se a hip?tese de que uma forma de particionamento ignorado pelas prescri??es normativas ? capaz de favorecer a evacua??o e o resgate dos ocupantes ao promover exaust?o da fuma?a no ambiente incendiado. A partir de um modelo representativo de um ambiente acad?mico constru?do, utilizou-se a simula??o computacional para testar o desempenho de um tipo de compartimenta??o horizontal seletiva com diferentes combina??es de aberturas para exaust?o da fuma?a. Nos resultados obtidos demonstrou-se que a compartimenta??o horizontal seletiva ? capaz de promover benef?cios para os ocupantes durante a evacua??o, tanto por promover maior altura da camada livre de fuma?a, quanto por retardar o instante em que a temperatura limite para a sobreviv?ncia humana ? atingida. / The thesis presents the results of research that addresses the performance of selective horizontal partitioning to promote Fire Safety in Buildings - FSB. Horizontal partitioning is a passive protection measure, settable in the early stages of the design process and controlled by the architect. However, there is a frequent reconfiguration of the rooms in academic buildings to adjust them for the space demand. Thus, large classrooms could turn into two or more smaller rooms, for example. Regardless when the subdivision occurs in the design phase or during the occupation of the building, the regulations just ensures the compartimentation of the room if all fireguard devices are present in the room. Knowing the fire's first minutes are the most important for life protection, we defend the hypothesis that a kind of partitioning ignored by regulatory standards is able to favoring the building vacancy and occupants rescue, for promote the room?s smoke exhaust. The performance of the selective horizontal partitioning due different blend of openings for smoke outlet was simulated on CFD software. The results indicate that selective horizontal partitioning is able to promote an upper smoke free layer and delay the indoor temperature growth.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/21137
Date12 April 2016
CreatorsCunha, Leonardo Jorge Brasil de Freitas
Contributors14594952844, http://lattes.cnpq.br/3789406301829141, Braga, George Cajaty Barbosa, 51763761134, http://lattes.cnpq.br/0157989523445444, Marinho, George Santos, 35846852491, http://lattes.cnpq.br/0490476694313938, Goulart, Solange Virginia Galarca, 46912517072, http://lattes.cnpq.br/3736189855910739, Silva, Valdir Pignatta e, 89456122891, http://lattes.cnpq.br/2431468701531047, Pinto, Edna Moura
PublisherUniversidade Federal do Rio Grande do Norte, PROGRAMA DE P?S-GRADUA??O EM ARQUITETURA E URBANISMO, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN