Return to search

Estudo da eficiência energética dos terminais de passageiros do Aeroporto Internacional Porto Alegre/Salgado Filho pelo método Procel Edifica

Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-05-30T12:21:44Z
No. of bitstreams: 1
Talita de Albuquerque Barreto_.pdf: 3641892 bytes, checksum: f2e5a2fbe9ce56b1af55edb294e16c77 (MD5) / Made available in DSpace on 2017-05-30T12:21:44Z (GMT). No. of bitstreams: 1
Talita de Albuquerque Barreto_.pdf: 3641892 bytes, checksum: f2e5a2fbe9ce56b1af55edb294e16c77 (MD5)
Previous issue date: 2016-12-22 / Nenhuma / Uma ação importante para a sustentabilidade é a redução do consumo de energia, buscando atingir a eficiência energética dos edifícios. Os aeroportos têm incorporado progressivamente operações comerciais e de lazer que os aproximam de centros comerciais, com um aumento no consumo de energia para iluminação artificial e condicionamento do ambiente considerando a operação 24/7. No entanto, muitas vezes não são desenvolvidos planos de eficiência energética. O Aeroporto Internacional Salgado Filho, localizado em Porto Alegre, sul do Brasil, tem cerca de 100 mil operações de aeronaves, entre pousos e decolagens, por ano, o que representa 4% do movimento nacional. Nesse contexto, este estudo tem como objetivo avaliar a eficiência energética do aeroporto mencionado. Este trabalho utiliza como parâmetro a certificação brasileira PROCEL Edifica. Foram coletados dados de consumo de energia de dois anos de operação do aeroporto. A eficiência energética foi avaliada através de condições técnicas de edifícios e sistemas operacionais, seguida por análise e classificação pelo método PROCEL Edifica. Os resultados apontaram para classificação geral da edificação como C no terminal 1 e classificação A no terminal 2. Os sistemas de iluminação e condicionamento de ar tiveram classificação abaixo do nível A e a partir da identificação de itens não atendidos do método, foram propostas ações para a redução do consumo de energia no aeroporto com a análise da viabilidade econômica dessas propostas. / An important action for sustainability is the reduction of energy consumption, seeking to achieve the energy efficiency of buildings. Airports have progressively incorporated commercial and leisure operations that bring them closer to shopping centers, with an increase in energy consumption for artificial lighting and environmental conditioning considering the operation 24/7. However, energy efficiency plans are often not developed. Salgado Filho International Airport, located in Porto Alegre, southern Brazil, has about 100,000 aircraft operations, between landings and takeoffs, per year, which represents 4% of the national movement. In this context, this study aims to evaluate the energy efficiency of the mentioned airport. This work uses as a parameter the Brazilian certification PROCEL Edifica. Energy consumption data from two years of airport operation were collected. Energy efficiency was evaluated through technical conditions of buildings and operating systems, followed by analysis and classification by PROCEL Constructs method. The results pointed to the overall classification of the building as C at terminal 1 and classification A at terminal 2. Lighting and air conditioning systems were rated below level A and from the identification of unmet items of the method, actions were proposed to reduce energy consumption at the airport with the analysis of the economic viability of these proposals.

Identiferoai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/6312
Date22 December 2016
CreatorsBarreto, Talita de Albuquerque
Contributorshttp://lattes.cnpq.br/8430945431911323, González, Marco Aurélio Stumpf
PublisherUniversidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Arquitetura e Urbanismo, Unisinos, Brasil, Escola Politécnica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0012 seconds