Submitted by Simone Souza (simonecgsouza@hotmail.com) on 2017-10-13T15:27:15Z
No. of bitstreams: 1
DISS_2014_Luciana Oliveira da Silva Lima.pdf: 5079399 bytes, checksum: 88f713ee31918d76cd02f42ec13a598c (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-11-07T10:32:24Z (GMT) No. of bitstreams: 1
DISS_2014_Luciana Oliveira da Silva Lima.pdf: 5079399 bytes, checksum: 88f713ee31918d76cd02f42ec13a598c (MD5) / Made available in DSpace on 2017-11-07T10:32:24Z (GMT). No. of bitstreams: 1
DISS_2014_Luciana Oliveira da Silva Lima.pdf: 5079399 bytes, checksum: 88f713ee31918d76cd02f42ec13a598c (MD5)
Previous issue date: 2014-02-21 / CAPES / Em projetos de eficiência elétrica, que envolve a troca de equipamentos convencionais por eficientes, existe a dificuldade de se estimar o consumo de energia elétrica ativa e a demanda de potência ativa, antes e após a execução do projeto. Porém, o software EnergyPlus tem se mostrado uma ferramenta eficaz para simulações termo energéticas, permitindo retratar os sistemas avaliados com operação muito próxima ao sistema real. Diante do expressivo aumento e a consequente necessidade do controle do consumo de energia elétrica pelo setor residencial, este trabalho propões analisar a viabilidade técnica e econômica do projeto de eficiência energética em unidades consumidoras “baixa renda”, que realiza na troca de refrigeradores antigos e ineficientes por refrigeradores novos com volume interno de armazenamento de 300 litros e Selo Procel classe A no consumo de energia elétrica, a substituição de lâmpadas incandescentes por lâmpadas fluorescentes compactas de 20W e a economia de energia de uma edificação residencial com a melhoria da sua envoltória. Desta forma, foi modelada uma edificação tipo no EnergyPlus, e realizada a simulação com o refrigerador e lâmpadas, antes e após o processo de substituição, para estimativa do consumo de energia elétrica ativa e da demanda de potência ativa. Com base nesta estimativa de redução de consumo e de demanda, foi calculada a relação Custo-Benefício do projeto pela simulação computacional e pelo método convencional, estipulado pelo Manual de Eficiência Energética da Aneel. Foi determinado o nível de eficiência energética de uma casa popular tipo, segundo o Método Prescritivo do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R). Também foi proposta uma nova modalidade de projeto de eficiência energética voltada para a melhoria da envoltória de residências, avaliando o impacto na redução do consumo e demanda de potência ativa e sua relação Custo-Benefício. / In electrical efficiency projects , which involves the exchange of conventional equipment with efficient , there is the difficulty of estimating the consumption of active power and active power demand before and after project implementation . However , EnergyPlus software has proven an effective tool for simulations energy term , allowing portray the systems evaluated with very close to the real system operation. Given the significant increase and the consequent need to control the power consumption by the residential sector , this paper proposes to analyze the technical and economic feasibility of the project on energy efficiency in consumer units "low income " , which performs the exchange of old and inefficient refrigerators for with new internal storage volume of 300 liters and Procel class A in energy consumption , replacing incandescent bulbs with compact fluorescent lamps and 20W energy saving of a residential building with improved envelope their refrigerators . Thus , one type building was modeled in EnergyPlus , and performed the simulation with the cooler and lamps before and after the replacement process for estimating consumption of active power and active power demand . Based on this estimated reduction of consumption and demand, the cost - benefit ratio of the project by computer simulation and by the conventional method stipulated by the Energy Efficiency Manual Aneel was calculated . The level of energy efficiency of a popular house type was determined according to the Prescriptive Method Quality Technical Regulation for the Level of Energy Efficiency of Residential Buildings (RTQ-R) . A new type of energy efficiency project aimed at improving the envelope of residences were also proposed for assessing the impact on reducing consumption and demand of active power and its cost-effectiveness .
Identifer | oai:union.ndltd.org:IBICT/oai:localhost:1/522 |
Date | 21 February 2014 |
Creators | Lima, Luciana Oliveira da Silva |
Contributors | Vasconcellos, Arnulfo Barroso de, Vasconcellos, Arnulfo Barroso de, Nogueira, Marta Cristina de Jesus Albuquerque, Rodrigues, Kleiber David, Malheiro, Teresa Irene Ribeiro de Carvalho |
Publisher | Universidade Federal de Mato Grosso, Programa de Pós-Graduação em Engenharia de Edificações e Ambiental, UFMT CUC - Cuiabá, Brasil, Faculdade de Arquitetura, Engenharia e Tecnologia (FAET) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFMT, instname:Universidade Federal de Mato Grosso, instacron:UFMT |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0175 seconds