Return to search

Estudo do aterramento dos pés de torres de linha de transmissão frente às descargas atmosféricas

Made available in DSpace on 2014-06-11T19:22:34Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-02-03Bitstream added on 2014-06-13T20:08:31Z : No. of bitstreams: 1
berardo_bl_me_bauru.pdf: 467989 bytes, checksum: 1b7cb5967b4080092b9a0c9ae7a58c49 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho mostra o estudo de uma linha de transmissão onde ocorreram desligamentos causados por descargas atmosféricas. Esse estudo foi feito a partir de informações de desligamentos de linhas de transmissão da concessionária e dados extraídos de um sistema de análise e monitoramento de descargas atmosféricas. Para esse trecho da linha de transmissão foram identificadas incidências de descargas atmosféricas que causaram desligamentos, bem como descargas que não causaram desligamentos. Baseados nestas informações foram efetuadas medições em campo de resistência de aterramento dos contrapesos e da resistividade do solo, onde foi possível constatar através dos resultados que algumas torres apresentaram valores que ultrapassaram os valores normatizados. O levantamento dessas informações é o principal foco deste estudo, que visa fornecer subsídios para a identificação de torres problemáticas. Uma proposta clássica utilizada para melhorar o desempenho desta linha de transmissão frente à incidência de descargas atmosféricas foi testada mas seu resultado não foi muito satisfatário / This paper shows the study of a transmission line where outages occurred because of lightnings. The study was made from information that came from the power utility transmission line disconnection and data obtained from lightnings analyses and monitoring system. For this part of the transmission line it was identified incidence of lightning that caused outages, as well as incidences that did not cause outages. Based on this information, it was performed field measurements of ground resistance counterpoise and resistivity where is was possible to find, trough the results that some of the towers present numbers trepassed the normal values. Coming up with this information is this information is the main goal of this study that aims to offer to identify the towers that contains problems. A classical proposal used to improve the performance of this transmission line facing the incidence of lightnings was tested but the result wasn't very satisfactory

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/87185
Date03 February 2012
CreatorsBerardo, Benício Luiz [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Martins, André Christóvão Pio [UNESP], Souza, André Nunes de [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format58 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0025 seconds