This diploma thesis’s focuses on the mechanical design of fast solenoid throttle valve for DCC semiactive damper. Current DCC dampers work with a time response of over 10 ms, which is not suitable for fast semiactive control of vehicle chassis. The time response needs to be shortened, to improve quality of regulation. The required time response is archived by new fast electromagnetic actuator for original CES valve. The actuator has been accelerated by reducing induction of eddy currents and by reducing weight of moving parts. New valve helped to reduce the time response of damper by 28 % to 8,1 ms. The results proved, that the time response is affected more by speed of the servo effect, which is closing main orifice, than by electromagnetic actuator. There is no more potential in accelerating CES valve by actuator.