Orientador: Fábio Luiz Camargo Villela Berbert / Banca: Flaviana Bombarda de Andrade / Banca: Juliane Maria Guerreiro Tanomaru / Resumo: O presente estudo avaliou o efeito da fototerapia com o laser de baixa intensidade (LBI) infra-vermelho próximo (InGaAsP: LASERTable; λ780 ± 3 ɳm, 25 mW) em linhagem celular de macrófagos de camundongos (RAW 264.7) expostos à diferentes cimentos endodônticos. Os grupos foram divididos de acordo com o material obturador e a presença ou não de irradiação, além dos grupos controle, sendo: G1: controle negativo - somente células, G2: células + laser, G3: controle positivo - LPS, G4: LPS + laser, G5: Endofill, G6: Endofill + laser, G7: AH Plus, G8: AH Plus + laser, G9: Sealapex e G10: Sealapex + laser. A viabilidade celular foi determinada por meio do teste de MTT e a produção de óxido nítrico (NO) pelo método de Griess. A irradiação com LBI influenciou significativamente a viabilidade de macrófagos expostos aos três materiais obturadores (p<0,001), sendo que o G8 foi o que resultou em maior número de células viáveis (p<0,001). Não houve interferência do LBI sobre a produção de óxido nítrico em nenhum dos grupos estudados. Concluiu-se que todos os cimentos endodônticos permitiram índices significativamente maiores de viabilidade celular quando da aplicação do LBI; o cimento AH Plus apresentou aumento significativamente maior de viabilidade dos macrófagos em relação aos demais cimentos quando da aplicação 18 do LBI , seguido do Sealapex e Endofill; o LBI não interferiu de forma significativa na produção de NO por parte dos macrófagos expostos a nenhum dos cimentos endodônticos estudados / Abstract: The present study evaluated the effect of phototherapy with low intensity laser (LLLT) near infrared (InGaAsP: LASERTable; λ780 ± 3 ɳm, 25 mW) in cell line mouse macrophages (RAW 264.7) exposed to different sealers. All the groups were divided according to the filling material with presence or absence of irradiation: G1: negative control - only cells, G2: laser + cells, G3: positive control - LPS, G4: LPS + laser , G5: Endofill, G6: Endofill + laser, G7: AH Plus, G8: AH Plus + laser, G9, G10 and Sealapex: Sealapex + laser. Cell viability was determined using the MTT assay and production of nitric oxide (NO) by the Griess method. The irradiation with LLLT significantly affect the viability of macrophages exposed to three filling materials (p <0.001), and the G8 was resulted in a greater number of viable cells (p <0.001). There was no interference from the LBI on nitric oxide production in any groups. It was concluded that all the sealers was significantly higher levels of cell viability when applying the LBI, and the AH Plus showed significantly greater viability of the macrophages relative to the other cements when applying the LBI, and followed by Sealapex Endofill; the LBI didn't interfere significantly in the production of NO by macrophages exposed to any sealers studied / Mestre
Identifer | oai:union.ndltd.org:UNESP/oai:www.athena.biblioteca.unesp.br:UEP01-000701413 |
Date | January 2012 |
Creators | Rabello, Ariele Patricia. |
Contributors | Universidade Estadual Paulista "Júlio de Mesquita Filho" Faculdade de Odontologia (Campus de Araraquara). |
Publisher | Araraquara : [s.n.], |
Source Sets | Universidade Estadual Paulista |
Language | Portuguese |
Detected Language | Portuguese |
Type | text |
Format | 90 f. : |
Relation | Sistema requerido: Adobe Acrobat Reader |
Page generated in 0.002 seconds