With their various structures and operations, the operational magnetic flux densities inside those energy conversion mechanisms are non-uniformly distributed, hence large deviations are exhibited among the actual and the estimated values of iron losses in those electric machines. The available datasheets provided by the steel manufacturers derived from standard measurement systems can only cover some typical information, accuracies of applying these data for related machine performance evaluations at those operational conditions are always uncertain. To establish more convincing datasheet for the calculation of iron loss in machines, standing between the steel manufacturers and the electric machine designers, the application of improved magnetic circuits analysis and the numerical Epstein Frame is proposed. The static transformers and the rotary synchronous switched-reluctance motors will be thoroughly calculated for illustrations. Based on the aforementioned datasheets and the iron losses evaluation procedure, when designing the similar machines, the iron losses could be appropriately estimated, and more detailed information could be supplied.
Identifer | oai:union.ndltd.org:NSYSU/oai:NSYSU:etd-0906110-122245 |
Date | 06 September 2010 |
Creators | Liu, Li-Yang |
Contributors | Li Wang, Cheng-Tsung Liu, Chang-Chou Hwang, Tzeng-Shong Yeh |
Publisher | NSYSU |
Source Sets | NSYSU Electronic Thesis and Dissertation Archive |
Language | Cholon |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0906110-122245 |
Rights | not_available, Copyright information available at source archive |