Previous issue date: 2014-07-31 / No Brasil, o controle da qualidade do ?leo Diesel comercializado ? realizado por monitoramento de propriedades f?sico-qu?micas, caracter?sticas do combust?vel atrav?s das Resolu??es ANP n? 65 de 09 de dezembro de 2011 e n? 45 de 20 de dezembro de 2012, que determinam os limites de especifica??o para cada par?metro e as metodologias de an?lise que devem ser adotados. No entanto, esses m?todos, apesar de bastante consolidados, possuem alguns inconvenientes t?cnicos, que levaram ao estudo de m?todos alternativos mais r?pidos e de menor custo. Este trabalho realizou uma avalia??o da aplicabilidade de equa??es matem?ticas dispon?veis na literatura e de Redes Neurais Artificiais (RNAs), na determina??o de par?metros de especifica??o do ?leo diesel. Foi realizado um levantamento bibliogr?fico das principais correla??es adequadas para a determina??o de propriedades do diesel, as quais foram aplicadas para obten??o do ponto de fulgor e do ?ndice de cetano, al?m da aplica??o, de forma mais resumida, para predizer propriedades do petr?leo. Para este estudo, foram utilizadas 162 amostras de diesel, com teores m?ximo de enxofre, 50 ppm, 500 ppm e 1800 ppm, que foram analisadas, em laborat?rio especializado, por meio de metodologias ASTM normatizadas pela ANP, com um total de 810 ensaios. Resultados experimentais das amostras de diesel, destila??o atmosf?rica, ASTM D86, e massa espec?fica, ASTM D4052, foram utilizados como vari?veis b?sicas de entrada para as equa??es avaliadas. As RNAs foram avaliadas para a predi??o do ponto de fulgor, ?ndice de cetano e teores de enxofre (S50, S500, S1800) e, nesta parte do trabalho foram testados dois tipos de arquiteturas de rede, feed-forward backpropagation e generalized regression, variando os par?metros da matriz de entrada de forma a determinar o grupo de vari?veis e melhor tipo de rede para predi??o das vari?veis de interesse. Os resultados obtidos pelas equa??es e pelas RNAs foram comparados com resultados experimentais obtidos por metodologias padr?o, utilizando o teste n?o param?trico de Mann-Whitney e test t de student, ao n?vel de signific?ncia de 5%, assim como pelo coeficiente de determina??o e erro percentual. Os resultados obtidos pela equa??o aplicada para o ponto de fulgor apresentou um erro de 27, 6 %, contudo observou-se uma tend?ncia um tanto similar aos resultados padr?o. O ?ndice de cetano foi obtido por tr?s equa??es, e ambas apresentaram bons coeficientes de correla??o, com destaque para equa??o baseada no ponto de anilina, que apresentou o menor erro de 0,8 %. As equa??es aplicadas ao petr?leo foram trabalhadas de forma a identificar perspectivas de trabalhos futuros, que se mostram bastante promissores. As RNAs para predi??o do ponto de fulgor e do ?ndice de cetano mostraram resultados bastante superiores ao observados com as equa??es matem?ticas, com erros respectivamente de 2,5% e 0,2%. Para os teores de enxofre S50, S500, e S1800, as RNAs constru?das utilizando como dados de entrada a destila??o D86 (T10, T50, T85 e T90), Massa Espec?fica, ?ndice de Cetano e Ponto de Fulgor apresentaram os melhores resultados. Dentre os teores de enxofre as RNAs conseguiram melhor predizer o S1800, e o erro obtido a partir dos resultados das RNAs aumentou com a diminui??o do teor de enxofre. De um modo geral, as redes do tipo feed-forward mostraram-se superiores as generalized regression. / Diesel fuel is one of leading petroleum products marketed in Brazil, and has its quality
monitored by specialized laboratories linked to the National Agency of Petroleum, Natural
Gas and Biofuels - ANP. The main trial evaluating physicochemical properties of diesel are
listed in the resolutions ANP N? 65 of December 9th, 2011 and N? 45 of December 20th, 2012
that determine the specification limits for each parameter and methodologies of analysis that
should be adopted. However the methods used although quite consolidated, require dedicated
equipment with high cost of acquisition and maintenance, as well as technical expertise for
completion of these trials. Studies for development of more rapid alternative methods and
lower cost have been the focus of many researchers. In this same perspective, this work
conducted an assessment of the applicability of existing specialized literature on mathematical
equations and artificial neural networks (ANN) for the determination of parameters of
specification diesel fuel. 162 samples of diesel with a maximum sulfur content of 50, 500 and
1800 ppm, which were analyzed in a specialized laboratory using ASTM methods
recommended by the ANP, with a total of 810 trials were used for this study. Experimental
results atmospheric distillation (ASTM D86), and density (ASTM D4052) of diesel samples
were used as basic input variables to the equations evaluated. The RNAs were applied to
predict the flash point, cetane number and sulfur content (S50, S500, S1800), in which were
tested network architectures feed-forward backpropagation and generalized regression
varying the parameters of the matrix input in order to determine the set of variables and the
best type of network for the prediction of variables of interest. The results obtained by the
equations and RNAs were compared with experimental results using the nonparametric
Wilcoxon test and Student's t test, at a significance level of 5%, as well as the coefficient of
determination and percentage error, an error which was obtained 27, 61% for the flash point
using a specific equation. The cetane number was obtained by three equations, and both
showed good correlation coefficients, especially equation based on aniline point, with the
lowest error of 0,816%. ANNs for predicting the flash point and the index cetane showed
quite superior results to those observed with the mathematical equations, respectively, with
errors of 2,55% and 0,23%. Among the samples with different sulfur contents, the RNAs were
better able to predict the S1800 with error of 1,557%. Generally, networks of the type feedforward
proved superior to generalized regression.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/20773 |
Date | 31 July 2014 |
Creators | Oliveira, Fernanda Maria de |
Contributors | 27832155515, Silva, Edjane Fabiula Buriti da, 01236834402, http://lattes.cnpq.br/1736653643786951, Vitor Sobrinho, Eledir, 64656969915, http://lattes.cnpq.br/8488499388852606, Teixeira, Leonardo Sena Gomes, 67108059568, http://lattes.cnpq.br/5061261000226463, Santos, Luciene da Silva |
Publisher | Universidade Federal do Rio Grande do Norte, PROGRAMA DE P?S-GRADUA??O EM QU?MICA, UFRN, Brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds