A method to obtain the exact control-to-output and input-to-output transfer functions for switched DC-to-DC pulse-width modulated power converters is applied to different combinations of operating conditions such as continuous conduction mode (CCM), discontinuous conduction mode (DCM), and discontinuous voltage mode (DVM) and methods of control such as normal voltage mode (NVM), current programming mode (CPM), and V-squared control. The majority of these combinations have not previously had their transfer functions of interest derived to the accuracy provided by the method. The derivation of the method is covered, and the results from its application are verified by simulation. The simulation method is also justied and proposed as an improvement to the methods used by simulation engines for switched mode power supply design such as SIMPLIS.
Identifer | oai:union.ndltd.org:pdx.edu/oai:pdxscholar.library.pdx.edu:open_access_etds-1194 |
Date | 01 January 2011 |
Creators | Simmons, Justin French |
Publisher | PDXScholar |
Source Sets | Portland State University |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | Dissertations and Theses |
Page generated in 0.0018 seconds