Return to search

Výzkum účinnosti zesíleného odsávacího systému v kombinaci s pracovním stolem / The capture efficiency research of REEXS with the work bench

Proposed diploma work provides capture efficiency measurements of generated pollution captured by reinforced slot exhaust system in modification with work bench using tracer gas method. There are shown results of capture efficiency for traditional exhausting (no radial air added) and reinforced exhausting (using radial air supply effect) in this work. This study also conatins the comparison and discusion of obtained measurement results with measurement errors and uncertainties.

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:228036
Date January 2008
CreatorsPavlas, David
ContributorsPavelek, Milan, Janotková, Eva
PublisherVysoké učení technické v Brně. Fakulta strojního inženýrství
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess