Laser induced breakdown spectroscopy (LIBS) applied to the quantification of elements in fertilizers / Laser Induced Breakdown Spectroscopy (LIBS) applied to the quantification of elements in fertilizer

A capacidade do instrumento Laser Induced Breakdown Spectroscopy (LIBS) foi investigada para a possibilidade de atuar como uma ferramenta de quantificação. Um instrumento de baixo custo fechado do dispositivo de acoplamento de cargas (CCD) foi utilizado a fim de quantificar (K), (Ca), (Mn), (Mg), e (Cu) presente em 26 amostras de fertilizantes constituídos de diferentes matrizes, alguns fosfato de organo-mineral e outros de material inorgânico (quantificação de elementos presentes em fertilizante organominerais nunca tinha acontecido). Duas técnicas de referências foram utilizadas para validar as habilidades de quantificação: Plasma Acoplado Indutivo-Espectroscopia de Emissão Ótica (ICP-OES) e Espectroscopia de Absorção Atômica (AAS). O melhor pico representando cada elemento foi encontrado para produzir a melhor correlação entre cada pixel CCD e a concentração de elementos obtidos a partir das técnicas de referência. O pico mais adequado de LIBS foi tratado com um procedimento de normalização, a fim de corrigir os efeitos de matriz e as pequenas flutuações no plasma. Após o pico produzido por LIBS ser normalizado, foi linearmente montado contra os dados das duas técnicas de referência e duas curvas de calibração para cada um dos elementos foram construídas. Quando o procedimento de normalização não foi aplicado, valores de R-quadrado diminuiu entre 0,1-0,2 em quase todos os elementos. No entanto, entre os resultados produzidos pelas duas curvas de calibração, após o procedimento de normalização ser aplicado, os valores de correlação R-quadrado variaram de 0,8-0,98, o que foi considerado adequado para os elementos de interesse. O LOD para LIBS também foi calculado e verificou-se que quando os valores estavam abaixo do limite de determinação, a validade de LIBS como uma ferramenta de quantificação diminuiu. Além disso, uma análise de erro de validação cruzada foi feita com LIBS-ICP e LIBS-AAS, o que originou valores de erro de 22% - 28% para alguns dos elementos, quando todas as amostras foram incluídas. Mas quando as amostras abaixo do LOD foram excluídas, aqueles valores de erro desceram significativamente, e resultou na gama de 7% - 20%. Uma análise de validação cruzada também foi feita para as concentrações dos elementos determinados pelas técnicas de referência e esses resultados produziram valores de erro variando de 9% - 23%. As semelhanças entre os valores de erro LIBS e os valores de erro das técnicas de referência, dá credibilidade para a capacidade de LIBS para atuar como uma ferramenta para a quantificação de elementos presentes em fertilizantes compostos de diferentes matrizes. / The ability of the instrument Laser Induced Breakdown Spectroscopy (LIBS) was investigated for the possibility of acting as a quantification tool of analysis. A low-cost gated charged coupled device (CCD) was used in order to quantify (K), (Ca), (Mn), (Mg), and (Cu) present in 26 fertilizer samples made up of different matrixes, some of organic-mineral phosphate and others of inorganic material; evaluation of elements in organomineral fertilizers had never been done by LIBS. Two reference techniques were used in order to validate the quantification abilities: Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) and Atomic Absorption Spectroscopy (AAS). The best peak representing each element was found by finding the best correlation between each CCD pixel and the element concentration obtained from the reference techniques. The most appropriate peak from LIBS was treated with a normalization procedure in order to correct for physical matrix effects and small plasma fluctuations. After the LIBS peak was normalized, it was linearly fitted against the data from the two reference techniques, thus two calibration curves for each element were built. When the normalization procedure was not applied, R-squared values decreased between 0.1 - 0.2 in almost all the elements. However, amongst the results of the two calibration curves after the normalization procedure was applied, R-squared correlation values ranged from 0.8-0.98, which were considered adequate for the elements of interest. The LOD for LIBS was also calculated and it was found that when values were below the LOD, the validity of LIBS as a quantification tool decreased. Moreover, a cross-validation error analysis was done with LIBS-ICP and LIBS-AAS, which yielded error values of 22% - 28% for some of the elements when all samples were included, but when samples below the LOD were excluded, those error values went down significantly, and resulted within the range of 7% - 20%. A cross-validation analysis was also done for the element concentrations determined by the reference techniques and those results yielded error values ranging from 9%- 23%. The similarities between the LIBS error values and the reference techniques error values, gives credibility to the ability of LIBS to act as a tool for quantifying elements in fertilizers composed of different matrixes.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-20042017-101150
Date16 February 2017
CreatorsCervantes, Cesar
ContributorsMilori, Debora Marcondes Bastos Pereira
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguagePortuguese
TypeDissertação de Mestrado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0025 seconds