Return to search

Topologias de filtros híbridos de potência com número reduzido de chaves

Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-03-01T13:09:14Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Silva Filho, Luis Rodrigues da.pdf: 5874183 bytes, checksum: 60b4246d84e077fb2131d50faca19bd3 (MD5) / Made available in DSpace on 2016-03-01T13:09:14Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Silva Filho, Luis Rodrigues da.pdf: 5874183 bytes, checksum: 60b4246d84e077fb2131d50faca19bd3 (MD5)
Previous issue date: 2015-01-30 / CAPES / Atualmente, um grande número de computadores e outras cargas elétricas sensíveis
ligadas à rede elétrica são diretamente afetados por problemas de qualidade de energia. Uma das questões mais importantes está relacionada com as correntes harmônicas geradas pelo aumento do número de cargas não-lineares conectadas ao sistema elétrico, tais como retificadores a diodo e tiristores. Como consequência, estes harmônicos podem causar distorções na tensão, perdas adicionais no sistema de energia e mau funcionamento de equipamentos eletrônicos sensíveis. A literatura apresenta diferentes topologias de filtros híbridos de potência visando a compensação harmônica de corrente. Este trabalho apresenta o estado da arte de algumas topologias, realizando uma análise comparativa entre elas. Em comum, todas as topologias possuem um reduzido número de chaves. Adicionalmente, é apresentada uma nova topologia chamada six-switch two-leg hybrid power filter, que além de apresentar um número reduzido de chaves quando comparada a outras topologias com dupla compensação, é capaz de fornecer compensação total, mesmo para cargas com um alto conteúdo harmônico. Os resultados experimentais são apresentados para um protótipo, a fim de demonstrar que o desempenho de compensação harmônica da proposta cumpre a norma IEEE 519. / Nowadays, a large number of computers and other sensitive electrical loads connected to the power grid are directly affected by power quality problems. One of the most important issues is related to current harmonics generated by the increasing number of nonlinear loads connected to the power grid, such as diode and thyristor front-end rectifiers. As consequence, these harmonics can cause voltage distortions, additional losses in the power system and malfunction of sensitive electronic equipment. The literature presents several hybrid power filters topologies, aiming current harmonic compensation. This work presents some state of - art topologies with reduced number of switches and performs a comparative analysis among them. Additionally, a six-switch two-leg hybrid power filter topology, that presents a reduced number of switches when compared with dual topologies, is proposed. The solution is capable of providing fully compensation even for loads with high harmonic content. Experimental results, obtaneid by a prototype, are presented in order to demonstrate that the harmonic compensation performance meets the IEEE 519 standard.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/15544
Date30 January 2015
CreatorsSILVA FILHO, Luís Rodrigues da
ContributorsLIMONGI, Leonardo Rodrigues
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Engenharia Eletrica, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguageBreton
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds