Return to search

Comportamento de concretos reforçados com microfibras de polipropileno (PP), álcool polivinílico (PVA) e recicladas de poliéster (POL) em relação à retração por secagem restringida e às propriedades mecânicas

Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-10-17T12:52:51Z
No. of bitstreams: 1
Hinoel Zamis Ehrenbring_.pdf: 8050494 bytes, checksum: 6538a92632a1aa3f9d35c647159bef3f (MD5) / Made available in DSpace on 2017-10-17T12:52:51Z (GMT). No. of bitstreams: 1
Hinoel Zamis Ehrenbring_.pdf: 8050494 bytes, checksum: 6538a92632a1aa3f9d35c647159bef3f (MD5)
Previous issue date: 2017-08-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / itt Performance - Instituto Tecnológico em Desempenho da Construção Civil / UNISINOS - Universidade do Vale do Rio dos Sinos / Concretos com tecnologia avançada tornam-se cada vez mais comuns na indústria da construção civil. O desenvolvimento de produtos minerais e químicos fomenta a geração desses compósitos, possibilitando a inserção de insumos com desempenhos mecânicos melhorados. Todavia, mesmo com inúmeras vantagens, os novos concretos ainda se encontram suscetíveis à incidência de fissuras causadas pela retração. Sendo uma característica inerente às matrizes cimentícias, a retração, quando restringida, pode gerar manifestações patológicas, que prejudiquem a durabilidade da estrutura. Estudos vêm sendo
realizados com enfoque na mitigação dessas anomalias, utilizando reforços primários e secundários dentro da matriz cimentícia. Como alternativa, utilizando as fibras como reforços é possível garantir alterações nos comportamentos mecânicos da mistura, a exemplo da resistência à tração, fator de tenacidade, capacidade de deformação e controle de fissuração. Com isso, nessa pesquisa foram empregadas, de maneira isolada e híbrida, microfibras poliméricas em uma matriz cimentícia. As microfibras eram constituídas por polipropileno (PP), álcool polivinílico (PVA) e recicladas de poliéster (POL). Para tanto, avaliou-se o fenômeno da retração por secagem dos compósitos por meio do ensaio de anel restringido, resistência à compressão axial, resistência à tração na flexão, módulo de elasticidade e tenacidade. Conjuntamente, investigou-se a microestrutura dos compósitos, utilizando o ensaio de microscopia eletrônica de varredura (MEV), a fim de identificar a zona de interface entre o reforço e a matriz cimentícia, assim como a integridade física do reforço no concreto. Os compósitos com microfibras apresentaram maior retração por secagem, quando comparados à matriz referência, chegando a deformações superiores a 50 μm/m. Todas as misturas atingiram alto potencial de fissuração, sendo as amostras contendo microfibras de PP e PVA, as quais obtiveram a formação da fissura mais tardiamente (14 dias). Com relação à resistência à compressão axial e tração na flexão, a inserção de microfibras poliméricas promoveu a redução dos valores em relação à matriz referência. Todavia, o uso
de microfibras de PVA não promoveu a queda de resistência à tração na flexão da matriz. Já o fator de tenacidade das misturas com fibras foi superior em relação ao concreto referência, ampliando em até 38 vezes os resultados. Verificou-se que a zona de interface formada pelas microfibras de PVA foi menor, quando comparada às demais opções, o que comprovou os bons resultados proporcionados pelo reforço. Também foi possível observar que as microfibras recicladas de poliéster foram agredidas em meio alcalino, diferentemente das demais. / Concretes with advanced technology become increasingly common in the construction industry. The development of mineral and chemical products encourages the generation of these composites, allowing the insertion of inputs with improved mechanical performances. However, even with numerous advantages, the new concretes are still susceptible to the incidence of cracks caused by shrinkage. As an inherent characteristic of cementitious matrices, shrinkage, when restricted, can impair the quality of the structure and, as a result, generate pathological manifestations. Studies have been carried out focusing on the mitigation of these anomalies, using primary and secondary reinforcements within the cementitious matrix. As an alternative, the fibrous reinforcements guarantee changes in the mechanical behavior of the mixture, such as tensile strength, tenacity factor, deformation capacity and cracking control. Thus, in this research, isolated and hybrid polymer microfibers were used in a reference cementitious matrix. The filaments consisted of polypropylene (PP), polyvinyl alcohol (PVA) and recycled polyester microfibers (POL). For this, the phenomenon of the drying shrinkage of the composites was evaluated by means of the restricted ring test, axial compression strength, flexural tensile strength, modulus of elasticity and toughness.
The microstructure of the composites was investigated using the scanning electron microscopy (SEM), in order to identify the interface zone between the reinforcement and the cementitious matrix, as well as the physical integrity of the reinforcement in the concrete. The composites with microfibers presented greater drying shrinkage, when compared to the reference matrix, reaching deformations of more than 50 μm/m. All the blends reached a high cracking potential, with the samples containing PP and PVA microfibers which obtained cracking formation later (14 days). With respect to the compressive strength, the insertion of polymer microfibers significantly decreased the values in relation to the reference matrix. The toughness factor of the bundled mixtures was superior in relation to the reference concrete, increasing up to 38 times the results. On the other hand, the tensile strength in the flexion decreased values with the use of the filamentary reinforcements, except for the mixture with PVA microfibres. It was verified that the interface zone formed by the PVA microfibers was smaller, when compared to the other options, which proved the good results provided by the reinforcement. It was also possible to observe that recycled polyester microfibers were attacked in alkaline solution, unlike the others.

Identiferoai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/6703
Date28 August 2017
CreatorsEhrenbring, Hinoel Zamis
Contributorshttp://lattes.cnpq.br/9916860252080305, Quinino, Uziel Cavalcanti de Medeiros, Tutikian, Bernardo Fonseca
PublisherUniversidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Engenharia Civil, Unisinos, Brasil, Escola Politécnica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds