Orientador: Yaro Burian Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-18T15:41:19Z (GMT). No. of bitstreams: 1
Siqueira_GabrieladePaiva_M.pdf: 1004897 bytes, checksum: 434e195d542578fc2f9b88f6143f079d (MD5)
Previous issue date: 2011 / Resumo: Este trabalho apresenta o estudo do comportamento elétrico de lâmpadas fluorescentes compactas. Ele engloba a análise dos componentes da lâmpada e do circuito do reator, a análise da estabilidade do ponto de funcionamento dessas lâmpadas, o estudo das características estáticas e dinâmicas, criação de modelo matemático, simulações e experimentos. Também é analisado o fenômeno de cintilações em lâmpadas fluorescentes desligadas. Inicialmente foi feita a análise geral das características da lâmpada e dos reatores magnéticos e eletrônicos. Foi feita uma análise comparativa entre os reatores eletrônicos e magnéticos levando-se em consideração as principais características de uso: tamanho, custo, efeito estroboscópico e fator de potência. Em seguida foi estudando o comportamento estático da lâmpada fluorescente. Foi feita a análise da estabilidade do ponto de funcionamento da lâmpada em regime estático levando-se em consideração o circuito externo e a dinâmica do plasma. Verificamos que existe uma boa aproximação para a curva característica estática na região de interesse. Ainda em regime estático observamos que, com corrente constante, existe uma oscilação periódica não senoidal na tensão, sobrepostas à tensão constante, da ordem de até uma dezena de volts e com freqüências da ordem de 10 kHz. O comportamento dinâmico da lâmpada fluorescente foi estudado a partir das equações do circuito externo, da dinâmica da lâmpada e da aproximação da característica estática. Simulações na freqüência de distribuição de energia elétrica (60 Hz) foram comparadas com os resultados obtidos experimentalmente. Simulando também o funcionamento da lâmpada alimentada por tensões senoidais em freqüências mais elevadas verificamos que a tensão e a corrente na lâmpada tendem para curvas senoidais em fase, confirmando que ela tende a funcionar como resistor em altas freqüências. As experiências em alta freqüência confirmaram essa tendência. Também notamos, através da verificação dos circuitos dos reatores de diversas lâmpadas ao longo dos anos, que o filtro de entrada dos reatores eletrônicos das lâmpadas fluorescentes compactas comerciais foi suprimido. Fato que se revelou causador de um evento indesejável dessas lâmpadas: a ocorrência de emissão de lampejos de luz de baixa intensidade e curta duração em intervalos da ordem de 1 minuto por algumas lâmpadas fluorescentes compactas desligadas. Foi analisado o motivo e proposta uma solução para eliminar este fenômeno / Abstract: This work presents a broad study of the electrical behavior of compact fluorescent lamps. It includes an analysis of the lamp components and the circuit of the reactor; an analysis of the stability on the operating point of the lamp; a study of static and dynamic characteristics; a development of a mathematical model; simulations and experiments. It is also analyzed the phenomenon of sparkling in turned off fluorescent lamps. First it was made a general analysis of the characteristics of those lamps with magnetic and electronic reactors. Then it was made a comparative analysis between them considering the main usage characteristics: size, cost, stroboscopic effect and power factor. It was then studied the static behavior of fluorescent lamps. It was made an analysis of the stability on the operation point of the lamp in static regime considering not only the external circuit but also the plasma dynamic. It was shown that there is a good approximation for the static characteristic curve in the region of interest. We also observed that, with a constant current, the voltage has a periodic (but not sinusoidal) oscillation on top of a constant value of voltage. This oscillation of dozens of volts has a frequency of about 10kHz. The dynamic behavior of the fluorescent lamp was studied by using: the equation of the external circuit, the equation of the lamp dynamic and the equation of the approximation of the static characteristic. It was made simulations in the frequency of electric energy distribution (60Hz) and they were compared with the results obtained experimentally. When it was simulated the functioning of the lamp fed by sinusoidal voltage in high frequencies, we saw that both voltage and current in the lamp tend towards sinusoidal curves in phase, confirming that the lamp has a tendency to function as a resistor in high frequencies. The experiences in high frequencies confirmed this trend. We also saw, by looking at reactors circuits over the years, that the entrance filter was suppressed from electronic reactors of commercial compact fluorescent lamps. This fact revealed to be the cause of an undesirable effect of these lamps: the emission of flashes with small intensity and short duration in intervals of about a minute by some fluorescent lamps when they are turned off. It was analyzed the reason and it was proposed a solution to eliminate this phenomenon / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/260034 |
Date | 06 October 2011 |
Creators | Siqueira, Gabriela de Paiva |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Burian Junior, Yaro, 1940-, Junior, Yaro Burian, Kaiser, Walter, Pomilio, José Antenor |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 57 f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds