Return to search

Bremsstrahlung de elétrons no microtron do IFUSP: medidas, simulação e proposta de aplicação ao estudo da ressonância fluorescente nuclear / Electron Bremssthahlung in the IFUSP microton: measurements, simulation and proposal for a nuclear resonance fluorescence observation setup

Apresentam-se os resultados dos primeiros experimentos com o novo acelerador de elétrons do Laboratório do Acelerador Linear (LAL) do Instituto de Física da USP, cuja primeira fase de montagem encontra-se concluída. Adicionou-se uma linha de irradiação ao projeto original do Microtron, que permite usar o feixe de elétrons com 1,9 MeV de energia do injetor. Espectros de bremsstrahlung de elétrons em alvos finos de Ag e Au, observados a 30o e 60o em relação ao feixe, foram medidos com um detector coaxial de HPGe, cujas dimensões, inclusive do orifício interno e da camada morta do cristal, foram determinadas por medidas experimentais e simulações de Monte Carlo com o código MCNPX, a fim de estimar a resposta do detector para a deconvolução dos espectros. As secções de choque de produção de bremsstrahlung foram medidas tanto para todo o espectro observado (100 1910 keV) quanto para a região próxima ao tip (1700 1910 keV). Os resultados na região do tip concordam com as previsões dos códigos MCNPX e PENELOPE. As causas das discrepâncias observadas para energias menores que 1800 keV são discutidas. Apresenta-se também o projeto de um sistema de medidas de Ressonância Fluorescente Nuclear (NRF) para o estudo de excitações dipolares dos núcleos com fótons de bremsstrahlung, que se pretende usar assim que a energia dos elétrons do Microtron alcance 10 MeV. O projeto desse sistema leva em conta as particularidades da instalação do acelerador e da sala de irradiação e busca minimizar a radiação devida aos fótons espalhados nas paredes e aos nêutrons produzidos em reações fotonucleares. O comportamento dos elementos que conformam o sistema de NRF: radiador, colimador, blindagem dos detectores e coletor do feixe de fótons foram estudados por simulação em função das suas características dimensões, formas, materiais com o código MCNPX. Com o projeto final do arranjo experimental, avaliaram-se as intensidades de NRF que serão observadas pelos detectores de fótons com um alvo de 27Al, típico nesse tipo de medições, que indica a viabilidade desse tipo de experimento com o Microtron. / The results of the first experiments carried out in the new electron accelerator of the Linear Accelerator Laboratory (LAL) of the Physics Institute of Universidade de São Paulo are reported here. A 1.9 MeV beam line, which allows the use of the injector beam for experimental physics, was added to the original accelerator design. Electron bremsstrahlung spectra for Ag and Au thin targets observed at 30o and 60o with respect to the beam direction were collected in a HPGe coaxial detector, whose dimensions, including crystal inner hole dimensions and dead layer thickness, were estimated by means of combined experimental measurements and Monte Carlo simulations with the MCNP code, to evaluate the detector response function to perform the deconvolution of the spectrum. Cross sections for bremsstrahlung yield were determined for the entire measured energy range (100 1910 keV) and for the tip region (1700 1970 keV). The results in the tip region are in agreement with MCNPX and PENELOPE predictions. The possible causes for the disagreement at energies lower than 1800 keV are discussed. The design of a Nuclear Resonance Fluorescence (NRF) setup, aiming the study of dipolar excitations in nuclei with bremsstrahlung photons when the Microtron electron energy reaches 10 MeV, is also shown. The setup was designed with the characteristics of the Microtron building and facilities in mind, and searches to minimize the radiation caused by scattered photons and neutrons from photonuclear reactions. The behavior of the NRF setup elements: converter, collimator, detector shielding and photon beam dump, were studied by simulation as functions of their characteristics dimensions, shapes, materials using the MCNPX code. The spectral intensity to be observed by the photon detector in the designed NRF setup with a 27Al reference target, typical for NRF measurements, was assessed by simulation and shows the feasibility of this sort of experiment with the Microtron.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-30092011-152216
Date20 June 2011
CreatorsNeivy Lopez Pino
ContributorsNora Lia Maidana, Nilberto Heder Medina, Marcia de Almeida Rizzutto, Carmen Cecília Bueno Tobias, Hélio Yoriyaz
PublisherUniversidade de São Paulo, Física, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds