Submitted by Carmen Torres (carmensct@globo.com) on 2018-02-09T18:19:39Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoTeoricaExperimental.pdf: 8194258 bytes, checksum: f77ffbc7ca33b810191640d6636e3cee (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-02-20T18:19:52Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoTeoricaExperimental.pdf: 8194258 bytes, checksum: f77ffbc7ca33b810191640d6636e3cee (MD5) / Made available in DSpace on 2018-02-20T18:19:52Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoTeoricaExperimental.pdf: 8194258 bytes, checksum: f77ffbc7ca33b810191640d6636e3cee (MD5)
Previous issue date: 2017-08-10 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho faz uma avaliação do impacto do sombreamento em quatro sistemas experimentais instalados na área de testes do Grupo de Estudos e Desenvolvimento de Alternativas Energéticas - GEDAE. Esses sistemas estão subdivididos em: um sistema experimental que avalia o impacto do sombreamento a nível de módulo e três a nível de Sistema Fotovoltaico Conectado à Rede (SFCR). Foi avaliada a operação desses sistemas em termos de suas condições naturais e por meio de sombreamentos forçados, aqui denominados de sombreamentos simulados. Os resultados obtidos foram aplicados a modelos de previsão da operação sob condições de sombreamento e no cálculo de figuras de mérito usadas na avaliação de sistemas FV. Os resultados obtidos neste trabalho complementam estudos tradicionalmente empregados na avaliação do impacto do sombreamento, mas que se restringem à avaliação das curvas I-V e P-V sob condições características e, na maioria dos trabalhos, aplicadas somente a nível de módulo FV. Além disso, este trabalho traz alguns resultados específicos associados ao sombreamento de um SFCR constituído de conversores c.c- c.c a nível de módulo. / This work evaluates the impact of shadowing in four experimental systems installed in the test area of the Group of Studies and Development of Energy Alternatives – GEDAE. These systems are subdivided in: an experimental system that evaluates the shading impact on module level and three systems that evaluate this impact on grid-connected PV system (GCPV) level. System’s operation was evaluated in terms of its natural conditions and under forced shadowing, called simulated shadowing in this work. The obtained results were applied to models used under shadowing conditions and also to calculate performance metrics used in the evaluation of PV systems. The results obtained in this work complement studies traditionally applied to shadowing impact assessment, but such studies are limited to the evaluation of I-V and P-V curves under specific conditions and, in most cases, they apply only to PV module level. Furthermore, this work presents some specific results associated to the shadowing of a GCPV composed by dc-dc converters in a module level.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/9464 |
Date | 10 August 2017 |
Creators | RODRIGUES, Marinaldo de Jesus dos Santos |
Contributors | MACÊDO, Wilson Negrão |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | 1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0028 seconds