Return to search

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens / Development of analytical methods employing optical emission spectrometry to evaluate the level of elemental contaminants in samples of different origins

Submitted by Daniel Araujo Gonçalves null (daniel.araujogoncalves@gmail.com) on 2016-08-01T13:43:54Z
No. of bitstreams: 1
Goncalves_Tese_versão_final.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-02T19:00:04Z (GMT) No. of bitstreams: 1
goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Made available in DSpace on 2016-08-02T19:00:04Z (GMT). No. of bitstreams: 1
goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5)
Previous issue date: 2016-07-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, energético, cerveja, whiskey e cachaça. Não foi necessária preparação da amostra, a não ser uma simples diluição em HNO3 1% v v-1. A eficiência do SDA foi avaliada por experimentos de adição e recuperação e os resultados foram comparados com os métodos tradicionais de calibração externa (EC), o padrão interno (IS) e adição de padrão (AS). As recuperações médias por SDA para vários elementos avaliadas neste trabalho foram entre 90 e 99%. Para o método tradicional de adições padrão, por exemplo, as recuperações médias entre 101 e 122% foram obtidos para os mesmos analitos e amostras. No quarto estudo um MIP OES (MP-AES, Agilent 4200) foi utilizado para a determinação de Cd, Cr, Cu, Ni e Pb na matriz de óleo fusel onde emprega-se a calibração externa preparada em solução de 1% HNO3 e 1-propanol. Soluções contendo 5 e 50% da matriz v v-1 foram diluidas em 1-propanol e solução de óleo fúsel puro foram analisados. Não foram observados efeitos de matriz quando empregou-se a calibração com soluções de 1-propanol mesmo para determinações na amostra não diluída, com recuperações entre 90-109%. Os LODs para Cd, Cr, Cu, Ni e Pb em 1-propanol foram de 0,03; 0,009; 0,01; 0,007 e 0,04 mg L-1, respectivamente. O procedimento descrito para o MIP OES é uma abordagem simples, exata e precisa para rastrear análise de elementos de óleo fúsel. / In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample preparation except a simple dilution in HNO3 1% v v-1 . The efficiency of the SDA was evaluated by experiments of addition and recovery, and the results were compared with the traditional methods of external calibration (EC), the internal standard (IS) and addition of default (AS). Average recoveries for SDA to various elements evaluated in this study were between 90 and 99%. For the traditional method of standard additions, for example, the average recoveries between 101 and 122% were obtained for the same analytes and samples. In the fourth study a MIP OES (MP-AES, Agilent 4200), was used for the determination of Cd, Cr, Cu, Ni e Pb in the array of fusel oil where is used the external calibration solution prepared 1% HNO3 and1-propanol. Solutions containing 5 and 50% of the matrix v v-1 were dissolved in 1-propanol and fusel oil pure solution were analyzed. Matrix effects were not observed when it was calibration with 1-propanol solutions even for undiluted sample determinations, with recoveries between 90 - 109%. The LODs for Cd, Cr, Cu, Ni and Pb in 1-propanol were of 0,03; 0,009; 0,01; 0,007 and 0,04 mg L-1 , respectively. The procedure described for MIP OES is a simple, accurate and precise approach to trace elements analysis of fusel oil. / CAPES PDSE: 99999.002566/ 2014-01

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/141993
Date08 July 2016
CreatorsGonçalves, Daniel Araujo [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Santos, Mirian Cristina dos [UNESP], Donati, George L.
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation600, 600

Page generated in 0.003 seconds