Submitted by Carmen Torres (carmensct@globo.com) on 2018-02-09T18:27:05Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoGeradoresConectados.pdf: 3677555 bytes, checksum: cacdc89995e90a3cb08a7b651b188a31 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-02-21T16:54:16Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoGeradoresConectados.pdf: 3677555 bytes, checksum: cacdc89995e90a3cb08a7b651b188a31 (MD5) / Made available in DSpace on 2018-02-21T16:54:16Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_ImpactoGeradoresConectados.pdf: 3677555 bytes, checksum: cacdc89995e90a3cb08a7b651b188a31 (MD5)
Previous issue date: 2017-08-11 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Apesar de suas vantagens indiscutíveis, a geração distribuída (GD) pode afetar negativamente alguns aspectos da operação dos sistemas de energia elétrica, especialmente um ponto pouco explorado: a proteção das redes de distribuição de energia elétrica e sua interação com os sistemas de geração de energia baseados em inversores. Nesta dissertação, o impacto da GD conectada via inversor na coordenação religador-fusível de esquemas de proteção em redes de distribuição é minuciosamente estudado. Simulações são realizadas por meio do software DIgSILENT PowerFactory através de curtos-circuitos monofásicos e trifásicos considerando diferentes localizações de faltas e da GD, níveis de penetração e de operação, e outros aspectos que influem na descoordenação da proteção em um sistema de distribuição teste real do IEEE de 34 barras. A contribuição à corrente de curto-circuito de geradores baseados em inversores é também investigada por meio de simulações no modelo de transitórios eletromagnéticos do software. Os resultados mostraram que a elevada penetração da GD conectada via inversores aumenta a corrente de curto-circuito que passa pelo fusível e o faz operar mais rapidamente do que o religador em uma condição de falta, levando à perda de coordenação religador-fusível. É feita uma discussão geral dos resultados, identificando os eventuais cuidados adicionais que devem ser considerados a fim de manter a coordenação e seletividade entre as proteções de um sistema de distribuição. / Despite its many benefits, the Distributed Generation (DG) can adversely affect some aspects related to the operation performance of electrical power systems, especially a no so deeply explored point: the interaction between the protection systems and inverter-based power generation units. In this dissertation, the impact of inverter-based DGs units on the fuse-recloser coordination schemes used in distribution networks is thoroughly studied. The simulations were conducted using the software package DIgSILENT Power Factory through several single-phase and three-phase short circuits along the distribution network, considering different fault locations, penetration levels of DGs, operating conditions, and other aspects that impact over the protection miscoordination in an IEEE real test distribution system of 34 busbars. The contribution to the short-circuit current of inverter-based generators is also investigated through simulations on electromagnetic transients models available in the software. The simulation results shows that significant inverter-based DG penetration levels on distribution feeders increase the short-circuit current that passes through the fuse and make it operate faster than the recloser in a fault condition, leading to loss of fuse-recloser coordination in a time frame base. A general discussion of the results is performed, identifying some recommended corrective actions that should be considered in order to maintain the coordination and selectivity between the distribution system protection devices located throughout the network.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/9474 |
Date | 11 August 2017 |
Creators | CORDEIRO, Murillo Augusto de Melo |
Contributors | VIEIRA, João Paulo Abreu |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | 1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0019 seconds