The production of alumina involves the use of a process known as the Bayer process. This method involves the digestion of raw bauxite in sodium hydroxide at temperatures around 250°C. The resultant pregnant liquor then goes through a number of filtering and precipitation processes to obtain the aluminium oxide crystals which are then calcined to obtain the final product. The plant is situated in a sub tropical climate in Northern Australia and this combined with the hot nature of the process results in a potential for heat related illnesses to develop. When assessing a work environment for heat stress a heat stress index is often employed as a guideline and to date the Wet Bulb Globe Temperature (WBGT) has been the recommended index. There have been concerns over the past that the WBGT is not suited to the Northern Australian climate and in fact studies in other countries have suggested this is the case. This study was undertaken in the alumina plant situated in Gladstone Queensland to assess if WBGT was in fact the most suitable index for use or if another was more applicable. To this end three indices, Wet Bulb Globe Temperature (WBGT), Heat Stress Index (HSI) and Required Sweat Rate (SWreq) were compared and assessed using physiological monitoring of heart rate and surrogate core temperature.
A number of different jobs and locations around the plant were investigated utilising personal and environmental monitoring equipment. These results were then collated and analysed using a computer program written as part of the study for the manipulation of the environmental data . Physiological assessment was carried out using methods approved by international bodies such as National Institute for Occupational Safety & Health (NIOSH) and International Standards Organisation (ISO) and incorporated the use of a Physiological Factor developed to enable the comparison of predicted allowable exposure times and strain on the individual.
Results indicated that of the three indices tested, Required Sweat Rate was found to be the most suitable for the climate and in the environment of interest. The WBGT system was suitable in areas in the moderate temperature range (ie 28 to 32°C) but had some deficiencies above this temperature or where the relative humidity exceeded approximately 80%. It was however suitable as a first estimate or first line indicator. HSI over-estimated the physiological strain in situations of high temperatures, low air flows and exaggerated the benefit of artificial air flows on the worker in certain environments ie. fans.
Identifer | oai:union.ndltd.org:ADTP/217052 |
Date | January 1998 |
Creators | Di Corleto, Ross, mikewood@deakin.edu.au |
Publisher | Deakin University. |
Source Sets | Australiasian Digital Theses Program |
Language | English |
Detected Language | English |
Rights | http://www.deakin.edu.au/disclaimer.html), Copyright Ross Di Corleto |