Made available in DSpace on 2014-12-17T14:48:11Z (GMT). No. of bitstreams: 1
LarissaDB_DISSERT.pdf: 3842498 bytes, checksum: e8657330e1607f44d84347d7099efb65 (MD5)
Previous issue date: 2012-02-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work presents results of field and laboratory tests using a Dynamic Cone
Penetrometer, DCP. The tests were performed in order to evaluate the use of the
equipment in sand for the control of bearing capacity of shallow foundations and fill
compaction. For shallow foundations, the laboratory tests were conducted on sand
placed in a metallic mould by the method of sand pluviation. Although the results
show the inability to reproduce field conditions in the laboratory it was possible to
verify the ability of the DCP to identify less resistant soil layers. The DCP tests for the
analysis of compaction control were performed in a strong box with inside
dimensions of 1,40 m x 1,40 m and 0,70 m in height. The soil layers were compacted
with different densities though the use of a vibrating plate in order to obtain
correlations between penetration index, DPI, and soil relative density. Other tests
were also conducted to assess the influence of soil moisture on tests results. Among
other findings, the results showed the great potential for the use of DCP to control the
compaction of sand fills / Este trabalho apresenta resultados de ensaios com um penetr?metro din?mico de
cone, DCP, realizados em campo e em laborat?rio. Os ensaios foram realizados com
o objetivo de avaliar o uso do equipamento em areias para o controle da capacidade
de carga em funda??es diretas e da compacta??o de aterros. No caso da an?lise de
funda??es diretas, os ensaios em laborat?rio foram realizados com o solo preparado
em um cilindro met?lico atrav?s do m?todo da chuva de areia. Na execu??o de
funda??es diretas apesar dos resultados mostrarem a impossibilidade de reproduzir
em laborat?rio as condi??es de campo verificou-se a possibilidade do uso do DCP
para a detec??o de camadas de solo menos resistentes. Os ensaios
penetrom?tricos para controle de compacta??o foram conduzidos numa caixa de
ensaios com 1,40 x 1,40 m de base e 0,70 m de altura. A areia foi preparada na
caixa com diferentes compacidades utilizando-se uma placa vibrat?ria para a
obten??o de correla??es entre o valor do ?ndice de penetra??o din?mica do
penetr?metro, DPI, e a densidade relativa do solo. Alguns ensaios tamb?m foram
realizados com o intuito de avaliar a influ?ncia do teor de umidade no valor do DPI.
Entre outras conclus?es, os resultados mostraram o grande potencial de uso do
DCP no controle da compacta??o de aterros com areia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/14836 |
Date | 27 February 2012 |
Creators | Benevides, Larissa Dantas |
Contributors | CPF:82818819415, http://lattes.cnpq.br/6483888857335060, Santos J?nior, Olavo Francisco dos, CPF:35816384449, http://lattes.cnpq.br/1573496204231636, Viana, Paulo M?rcio Fernandes, CPF:66062411549, http://lattes.cnpq.br/4545240150317474, Costa, Yuri Daniel Jatob?, CPF:92610927487, http://lattes.cnpq.br/6737841388506901, Costa, Carina Maia Lins |
Publisher | Universidade Federal do Rio Grande do Norte, Programa de P?s-Gradua??o em Engenharia Civil, UFRN, BR, MEC?NICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds