Return to search

Early detection of blood loss using a noninvasive finger photoplethysmographic pulse oximetry waveform

Delayed control of haemorrhage or blood loss has been recognised as a major contributor to preventable trauma deaths, but early detection of internal bleeding is difficult due to unreliability of heart rate (HR) and blood pressure (BP) as markers of volume status. This thesis explores a novel method of early blood loss detection using a noninvasive finger photoplethysmographic (PPG) pulse oximetry waveform that is normally utilised in pulse oximeters for estimating arterial oxygen saturation. Graded head-up tilt (n = 13) and blood donation (n = 43) in human volunteers were selected as experimental models of mild to moderate blood loss. From the tilt study, a novel method for automatically detecting left ventricular ejection time (LVET) from the finger PPG waveform has been developed and verified by comparison with the LVET measured from aortic flow velocity. PPG waveform derived LVET (LVETp) and pulse transit time (PTT) were strongly correlated with aortic LVET and pre-ejection period respectively (median r = 0.954 and 0.964) and with the decrease in central blood volume indicated by the sine of the tilt angle (median r = -0.985 and 0.938), outperforming R-R interval (RRI) and BP in detecting mild central hypovolaemia. In the blood donation study, progressive blood loss was characterised by falling LVETp and rising PTT (p < 0.01). A new way of identifying haemorrhagic phases by monitoring changes and trends in LVETp, PTT and RRI has been proposed based on the results from the two studies. The utility of frequency spectrum analysis of PPG waveform variability (PPGV) in characterising blood loss has also been examined. A new technique of PPGV analysis by computing the coherence-weighted cross-spectrum has been proposed. It has been shown that the spectral measures of finger PPGV exhibited significant changes (p < 0.01) with blood donation and were mildly correlated with systemic vascular resistance in intensive care unit patients (r from 0.53 to 0.59, p < 0.0001), therefore may be useful for identification of different haemorrhagic phases. In conclusion, this thesis has established finger PPG waveform as a potentially useful noninvasive tool for early detection of blood loss.

Identiferoai:union.ndltd.org:ADTP/257934
Date January 2008
CreatorsChan, Gregory, Electrical Engineering & Telecommunications, Faculty of Engineering, UNSW
PublisherPublisher:University of New South Wales. Electrical Engineering & Telecommunications
Source SetsAustraliasian Digital Theses Program
LanguageEnglish
Detected LanguageEnglish
Rightshttp://unsworks.unsw.edu.au/copyright, http://unsworks.unsw.edu.au/copyright

Page generated in 0.0021 seconds