Return to search

Influência da temperatura sobre a microdureza de uma resina composta fotoativada com luz halógena e Leds

Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-08-31Bitstream added on 2014-06-13T19:51:22Z : No. of bitstreams: 1
caceresbenitez_p_me_arafo.pdf: 539913 bytes, checksum: 4b2674880d3cfaa5af955bceb1ed75eb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo desta pesquisa foi avaliar a influência de várias temperaturas sobre os valores de microdureza de topo e base de uma resina composta fotopolimerizável comercialmente disponível, variando o tipo de fonte de luz (LEDs e lâmpada halógena). As temperaturas testadas foram 25, 35, 45, 55, 65, 80, 90 e 100º C. A resina composta utilizada foi a Z100 (3M). Com o auxílio de uma matriz metálica foram confeccionados 3 corpos-de-prova de 2 mm de espessura e 9,8 mm de diâmetro para cada temperatura. Os corpos-de-prova foram polimerizadas LEDs (60 s) ou lâmpada halógena (40 s) enquanto eram submetidas às diferentes temperaturas, após a polimerização as amostras foram armazenadas a seco, em estufa a 37º C. Após 24 horas as amostras foram submetidas ao teste de microdureza Vickers no topo e na base. Baseados nos resultados conclui-se que com a elevação da temperatura aumentou o valor da dureza Vickers com correlação linear positiva e com ambos aparelhos; o valor da dureza de topo foi sempre superior à dureza de base independentemente da fonte de luz ou temperaturas empregadas; o aparelho de luz halógena só se mostrou superior à fonte de LEDs na região de base dos corpos-de-prova. / The aim of this research was to evaluate the influence of several temperatures on the microhardness values of top and base of a light curing composites resin commercially available, varying the type of light source (LEDs and halogen lamp). The tested temperatures were 25, 35, 45, 55, 65, 80, 90 and 100º C. The composite resin used was Z100 (3M). With the aid of a metallic mould were made three samples of 2 mm of thickness and 9,8 m diameter for each temperature. The samples were light cure while they where submitted to the different temperatures with LEDs (60 s) and halogen lamp (40 s), after the polymerization the samples were dry stored in a stove at 37º C. After 24 hours, the samples were submitted to the Vickers microhardness test in the top and in the base. Based on the results it was concluded that with the elevation of the temperature increased the Vickers hardness value with positive linear correlation on both devices. The hardness value of the top was always superior to the base hardness, independently of the light source or used temperatures. The halogen lamp source was superior to the source of LEDs in the area of base of the samples.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/89631
Date31 August 2004
CreatorsCáceres Benítez, Pablino [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Junior, Osmir Batista de Oliveira [UNESP], Bagnato, Vanderlei Salvador [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format101 f. : il.color.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0191 seconds