Return to search

Desenvolvimento e validação de método analítico empregando DLLME e HPLC/UV para determinação de benzodiazepínicos em amostra de água / Development and validation of analytical method employing DLLME and HPLC/UV for the determination of benzodiazepines in water sample

Orientador: Rodnei Bertazzoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T13:08:38Z (GMT). No. of bitstreams: 1
Marques_TamiresValim_M.pdf: 6834346 bytes, checksum: 5eb1bc6d88a438ca9002c92109a6c660 (MD5)
Previous issue date: 2014 / Resumo: A crescente preocupação com a poluição das águas por novos poluentes denominados emergentes tem se intensificado, visto que aumentou o número destes compostos detectados em água. Dentre estes compostos encontram-se os fármacos e produtos de higiene pessoal, usados cotidianamente pela população. O presente trabalho teve como objetivo o desenvolvimento de um método simples, rápido e sensível utilizando a microextração líquido líquido (DLLME) combinada com a cromatografia líquida de ultra eficiência (HPLC) com detecção ultravioleta (UV) para a determinação de alguns benzodiazepínicos (bromazepam, clonazepam e diazepam) em amostras de água. A determinação foi realizada em uma coluna C18 de acordo com as condições cromatográficas ótimas (fase móvel acetonitrila:água (60:40, v/v); vazão 1,2 mL min-1; detecção 225 nm). No método de extração, uma mistura apropriada de solvente extrator e dispersor foi injetada rapidamente na amostra aquosa (10 mL) com auxílio de uma seringa. De modo que uma solução turva foi formada, esta solução é caracterizada por conter pequenas partículas do solvente extrator que se dispersa na fase aquosa. Os parâmetros da extração, tais como natureza e volume dos solventes extrator e dispersor, tempo de extração, pH da amostra, força iônica, velocidade e tempo de centrifugação, foram estudados para a otimização. Com as condições ótimas definidas (solvente extrator: clorofórmio, 200 ?L; solvente dispersor: metanol, 700 ?L; pH da amostra 9,0; velocidade e tempo de extração: 5000 rpm, 1 minuto; força iônica: adição de 1% (p/v) de (NH4)2SO4) o método proposto foi validado seguindo as figuras de método preconizadas pela ANVISA na Resolução N° 899 de 2003. A faixa linear para cada fármaco foram 8,0 - 96 ?g L-1 para bromazepam, 4,0 - 48 ?g L-1 para clonazepam e 1,0 - 12 ?g L-1 para diazepam. Todas as curvas obtiveram valores de (r) superiores a 0,999. Os limites de detecção e quantificação obtidos foram 2,4 e 8,0 ?g L-1 para bromazepam, 1,2 e 4,0 ?g L-1 para clonazepam, 0,2 e 1,0 ?g L-1 para diazepam, respectivamente. As recuperações variaram de 50 a 110% com RSD (Desvio Padrão Relativo) inferiores a 12,7 %. Finalmente, o método proposto foi aplicado em amostras coletadas na represa Billings localizada no município de Diadema-SP. / Abstract: The growing concern over water pollution caused by so-called new emerging pollutants has intensified since increased the number of these compounds detected in water. Among these compounds are pharmaceuticals and personal care products used daily by the population. This study aimed to develop a simple, rapid and sensitive liquid using liquid micro extraction (DLLME) combined with ultra-performance liquid chromatography (HPLC ) with ultraviolet detection (UV) for the determination of some benzodiazepines (bromazepam, clonazepam and diazepam) in water samples . The determination was performed on a C18 column in accordance with the optimal chromatographic conditions (mobile phase acetonitrile: water (60:40, v/v), flow rate 1.2 mL min-1, detection 225 nm). In the extraction method, a suitable mixture of extractant and dispersing solvent was injected rapidly into the aqueous sample (10 ml) with a syringe. So that a cloudy solution was formed, this solution is characterized by containing fine drops of the extractor solvent is dispersed in the aqueous phase. The parameters of the extraction, such as the nature and volume of the extractor and disperser solvents, extraction time, sample pH, ionic strength, speed and time of centrifugation, were studied for optimization. With the defined optimal conditions (extracting solvent: chloroform, 200 ?L; disperser solvent: methanol, 700 ?L, sample pH 9.0, extraction time and speed: 5000 rpm, 1 minute; ionic strength: adding 1% (p/v) (NH4)2SO4) the proposed method was validated following the figures of merit recommended by the ANVISA Resolution No. 899 of 2003. The linear ranges for each drug were 8.0 to 96 ?g L- 1 for bromazepam, 4.0 to 48 ?g L- 1 for clonazepam and 1.0 to 12 ?g L- 1 for diazepam. All curves obtained values (r) greater than 0.999. The limits of detection and quantification obtained were 2.4 and 8.0 ?g L- 1 to bromazepam, 1.2 and 4.0 ?g L- 1 to clonazepam, 0.2 and 1.0 ?g L- 1 for diazepam, respectively. Recoveries ranged from 50 to 110% with RSD (Relative Standard Deviation) of less than 12.7%. Finally, the proposed method was applied to samples collected in the Billings dam located in Diadema-SP. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265966
Date02 December 2014
CreatorsMarques, Tamires Valim, 1987-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bertazzoli, Rodnei, 1965-, Rodrigues, Christiane de Arruda, Cadore, Solange
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format96 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds