This aim of task deals with study of heat dissipation mechanisms and the description of physical phenomena, which is accompanied by non-stationary measurement of thermal characteristics by the method "hot-wire method". In particular, we observe the coefficient of thermal conductivity and its dependence on various variables such as the temperature of the measured sample, its moisture state, the volume of the sample and its porosity. The above mentioned findings are used for the invention of the measuring device of a nonstationary gauge, which is based on regular heating and is dedicated to measuring the thermal conductivity coefficient and the heat capacity by the "hot-wire method" method. In the last part of the thesis is verified functionality of the proposed measuring device, the suitability of the created algorithm for the processing of the measured data and the evaluation of the results was verified. The reproducibility of the measurements was verified and the measured results were compared with the measurement methods, which are commonly used. the influence of humidity on the coefficient of thermal conductivity.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:401480 |
Date | January 2019 |
Creators | Průša, David |
Contributors | Čermák,, Jan, Šťastník, Stanislav |
Publisher | Vysoké učení technické v Brně. Fakulta stavební |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |
Page generated in 0.0018 seconds