Return to search

Perdas fisicas de agua em sistemas de abastecimento : metodo de diagnostico, controle e redução atraves de sistema de informações geograficas / Water losses in public water network supply : diagnostic, control and reduction method by the geographic information system

Orientador: Paulo Vatavuk / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T17:18:24Z (GMT). No. of bitstreams: 1
PaliniJunior_Luis_M.pdf: 15139226 bytes, checksum: aa068532965e118fcf5ad622f3471d4e (MD5)
Previous issue date: 2008 / Resumo: Atualmente a água para consumo humano caracteriza-se, cada vez mais, por agregar valor econômico e social, face à relação estratégica entre a sua demanda crescente em detrimento da oferta tendendo a escassez, principalmente nos grandes centros urbanos, desta forma, a ocorrência de elevados índices de perdas físicas nos sistemas de abastecimento de água constitui um grande problema a ser enfrentado visando à busca de soluções técnicas capazes de reduzir estes indicadores a níveis mínimos aceitáveis. Neste contexto, o presente trabalho busca demonstrar a relação entre, pressão dinâmica, idade e tipo de material da tubulação e a ocorrência de perdas físicas em rede de distribuição num sistema de abastecimento de água (SAA), propondo um modelo de diagnóstico e controle de perdas físicas, baseado na integração de um Sistema de Informações Geográficas (SIG) e um modelo hidráulico desenvolvido para a rede de distribuição na área de estudo, os quais em conjunto, reúnem informações do cadastro técnico, monitoramento de vazão (ofertada e consumida) e de pressão dinâmica, levantados na área de interesse, os dados de ocorrência de rupturas e fugas em redes e ramais de distribuição, levantados no sistema interno de serviços (SIS), procurando conferir ao processo de análise, dinamismo e confiabilidade. Através da coleta, manipulação e análise dos dados contemporâneos monitorados em campo e de correlações teóricas é possível a identificação de ocorrência de perdas físicas nos componentes do SAA, bem como, diagnosticar a localização aproximada promovendo maior agilidade operacional no controle e redução de perdas físicas. Para a aplicação prática, foi escolhida uma área piloto, denominada Ponte Grande, a qual configura dentre as áreas implantadas no âmbito das atividades do Comitê Interno de Controle e Redução de Perdas de Água (CICRP) para o Serviço Autônomo de Água e Esgoto (SAAE) do município de Guarulhos - S.P., para qual foi desenvolvido o modelo hidráulico e executadas campanhas de monitoramento de campo no interior área em questão, buscando levantar e/ou checar dados e informações necessárias à calibração do modelo hidráulico para a rede de distribuição primária e secundária existente no interior deste setor de monitoramento. Através dos dados de pressão dinâmica atuante, verificação do cadastro técnico de rede em campo, levantamento da demanda de consumo, foi possível estabelecer uma correlação com os dados de ocorrência operacionais indutoras de perdas físicas, permitindo algumas conclusões, quais sejam, verificar que as maiores incidências de perdas físicas ocorrem onde o gradiente de pressão dinâmica é elevado e, sobretudo onde este gradiente coincide com trechos de rede, cujas instalações são relativamente mais antigas e material em ferro fundido. É possível, com a ajuda deste estudo, avaliar a necessidade de remanejamento de redes, através de um plano priorizado pela idade e tipo de material instalado, visando à redução das perdas físicas de água. / Abstract: Nowadays, the water for human consumption has been adding social and economic considerable values, due to its strategic relationship between the increasing demand in detriment to the offer, tending to scarcity, mainly in the big centers, so the occurrence of high levels of physical losses, in the water supply system (WSS), has become a great problem to be faced, seeking for technical solutions that are able to reduce the indicators to the minimum acceptable levels. In this context the present dissertation wants to show the relationship between dynamic pressure, age and type of material of pipeline and physical losses in the water supply systems (WSS), offering a diagnostic and control model of physical losses, based on the integration of a Geographic Information Systems (GIS) and a hydraulic model, developed to the study area network supply, have joined information from the technical survey, monitoring the flowing (offered and consumed) and of dynamic pressure, shown in the interest area, as well as, the occurrence data of ruptures and leakage in the WSS, raised in the information system of services (SIS), trying to confer to the analysis process, dynamism and reliability. Through the assessment, manipulation and the analysis of the contemporary data, monitored in field and the theoretical correlations, it is possible to identify the occurrence of physical losses in the components of WSS, as well as, diagnose the close location, promotion more operational agility in the control and reduction of physical losses. To apply the practice, it is chosen a pilot area, called Ponte Grande, which had inserted in the established areas in the activities of the Committee for Internal Control and Reduction of Water Losses (ICRWL) for the Serviço Autônomo de Água e Esgoto (SAAE) in the municipality of Guarulhos-SP., to where, It was developed a hydraulic model and monitoring campaigns inside the area in question, seeking to get and check the data and the necessary information for the hydraulic model calibration to the primary and secondary water distribution network. Through the dynamic pressure data, network technical register verification, demand and consumption water data, it was possible to establish a correlation with physical losses operational occurrence data, allowing some conclusions, such as, verify that most of the incidences of physical losses occurs where the dynamic pressure gradient is high and, above all, where this gradient coincides with piping parts, whose installations are old and the material used was cast iron. It is possible, to evaluate, with this study, the necessity of replacing the piping, through a priority plan, according t the age and type of material used, seeking for the reduction of water physical losses. / Mestrado / Recursos Hidricos / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258749
Date14 August 2018
CreatorsPalini Junior, Luis
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Vatavuk, Paulo, 1960-, Junior, Edevar Luvizotto, Andrade, Jose Geraldo Pena de, Diniz, Victor Emanuel Mello de Guimarães
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format189 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds