Return to search

Stanovení arsenu v pivu a surovinách pro jeho výrobu / Arsenic determination in beer samples and raw materials for its preparation

This thesis describes the optimization of the method for determination of arsenic by the chemical hydride generation coupled with AAS detection in beer samples and raw materials for its preparation. The beer usually contain arsenic at ultratrace level, however, it is necessary to monitor the concentration of this element in the beer. The routinely used method for determination of arsenic is determination by electrothermal atomization. This approach is time consuming, expensive and less sensitive. It has been developer suitable determination of arsenic as a faster and less expensive method. For this method there was optimized the flow rate of argon to 75 ml·min-1, the optimum flow rate for the reagents was 4.0 ml·min-1 and for the sample 5.0 ml·min-1 . 3 % NaBH4 in 0.5 % NaOH was used as the reducing agent for the determination of arsenic, and HCl diluted 1:1 with distilled water was used to acidify the sample. With this parameter LOD was 0.32 μg·l-1 and LOQ 1.05 μg·l-1 . It has been tested the arsenic determination in samples of barley, malt and potable water as beer raw materials. It has been found that the beer matrix is unsuitable for the hydride generation technique due to a stormy reaction in the gas/liquid phase separator. The effect of pretreatment, which is likely to enhance the effect of...

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:365110
Date January 2017
CreatorsŠvadlenová, Veronika
ContributorsHraníček, Jakub, Jelínek, Ivan
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess

Page generated in 0.0022 seconds